When turning the screw 360° once in direction (+) the pressure always
raises up 1 bar.
The perfect / ideal working pressure is appr. 6 bar.
g) While operation of the sprinkler, there is the possibility to adjust the desired irrigation
sector on the spring stop [18].
h) After the complete ventilation of the sprinkler the manual operating must be set on position
„AUTO“ , than the sprinkler have to close.
i) Check electrical function by turning on and off the sprinkler with help of a control unit.
5.2 Winterise
Before beginning of the frost period the sprinkler has to be totally drained off.
Therefore there must be connected a powerful compressor on the network / main circuit.
Open the valve on the sprinkler until only air is coming out of the nozzle.
After the blowing out the magnetising coil has to be triggered electrically several times.
6. Maintenance
Clean interior space of the sprinkler with a industrial type vacuum cleaner or a similar device.
Clean / Relieve sprinkler housing from overgrown grass. This work should be done
conveniently before commissioning in spring.