background image

Features

Highly Refined Circuit Design

All Perreaux analogue amplification stages are based on circuits that have 
been extensively optimised over many years of continuous development.  
By starting with excellent circuit designs and working with them over the 
years, we are able to discover the many small refinements that add up to 
superlative performance, in a variety of applications.

Capacitor-Free Signal Path

The inputs of the éloquence 150i are DC coupled and there is not a 

single capacitor in the signal path that the audio signal passes through, 

improving low-frequency response and linearity.  There are no capacitors 
to degrade over time and hinder performance, so the amplifier will essen-
tially sound the same years after its initial purchase. 

Precision Volume Control

The éloquence 150i uses a solid-state stepped attenuator offering precise 
resolution with exceptional channel matching.  The sealed package and 
lack of mechanical contacts, results in an ageless volume control – wiper 
noise and component drift is a thing of the past.

Non-Invasive Balance Control

Balance control in the éloquence 150i is accomplished without the addi-

tion of any further circuitry, thereby removing its potential effects on the 

audio signal.  The balance control benefits from the same precise resolu-
tion offered by the volume control.

MOSFET Technology

As with all Perreaux products, the éloquence 150i integrated amplifier 
capitalises on the benefits of using MOSFET technology in its output 
stages – excellent high-frequency response, improved distortion perform-
ance and reliability.

Balanced Input

The éloquence 150i features a balanced input via XLR connectors, allow-
ing optimal performance with the many high-end CD players and other 
audio components that utilise the benefits of balanced outputs.

Intuitive User Interface

The interface knob on the front panel of the éloquence 150i is the heart 

of the user interface experience – allowing fundamental control of the 

volume, and intuitive navigation and adjustment within the éloquence 
menu system.

Highly Customisable

Many settings of the éloquence 150i are user customisable – inputs may 

be named appropriately, select only inputs that are used, precisely match 
volume levels between inputs, set inputs to bypass the volume control, 

set initial and maximum volumes.  Essentially, the amplifier can operate 
as if it were custom designed for your system.  These are only a selection 
of the available settings you can customise; continue reading for discus-
sion on other customisable settings.

Infrared Remote Control 

The supplied infrared (IR) remote control offers complete control over the 
éloquence 150i in a small and functional package.  External control by IR 
is also offered via the IR input on the rear panel, should the amplifier be 
inside a cabinet or outside line-of-sight of the remote control.

Smart Home Integration

The éloquence 150i can easily be integrated into any smart home, using 
the RS-232 port at the rear of the amplifier and interfacing to devices 
from the likes of Control4™, AMX™ and Crestron™.  Coupled with the IR 
input, smart home integration has never been easier.

 

5

Summary of Contents for eloquence 150i

Page 1: ...Owners Manual loquence 150i Integrated Amplifier PERREAUX...

Page 2: ......

Page 3: ...loquence 150i Integrated Amplifier Designed and Manufactured in Dunedin New Zealand...

Page 4: ...g information in the instruction and service manuals Mains Plugs This device is supplied with a non rewireable mains plug for the intended country Replacement mains leads can be obtained from your Per...

Page 5: ...supply only of the type described in the operating instructions and or as marked on the rear of the unit General Safety Instructions DO NOT defeat the safety earth of the grounding type mains plug se...

Page 6: ...use only is subject to Copyright and Acknowledgments Table of Contents Volume Configuration 20 Initial Volume 20 Maximum Volume 20 Balance 20 Ramp 20 Mute Level 21 Bypass 21 Volume Trim 21 Clock 21 Ad...

Page 7: ...investment in Perreaux Perreaux products are designed to provide the utmost in sonic realism and electronic reliability with a functional yet elegant appearance that reflects the care and craftsmansh...

Page 8: ...technology in its output stages excellent high frequency response improved distortion perform ance and reliability Balanced Input The loquence 150i features a balanced input via XLR connectors allow...

Page 9: ...ship with which they are assembled and the exhaustive inspection and testing we employ help raise the value of Perreaux products In addition to yielding the best performance careful attention to detai...

Page 10: ...is used in a cabinet air must be able to flow through An enclosed cabinet will severely restrict heat dissipation Ensure that nothing is placed above or below the amplifier that might block or restri...

Page 11: ...priate speaker binding posts at the rear of the amplifier Switch on source component Turn on the source component making sure you have your favourite recording ready to play Switch on your loquence 15...

Page 12: ...anced output source to verify that the pin assignments of the output connectors correspond to the loquence 150i If this is not the case wire the cables so that the appropri ate output pin connects to...

Page 13: ...4 Tape Out The unbalanced RCA tape outputs provide a single ended line level audio signal suitable for recording from the selected source input This output is disconnected when INPUT 5 is selected to...

Page 14: ...mplifier with power Prior to connection to the AC mains please check the voltage label on the rear panel to ensure that your amplifier conforms to the power supply in your area Never attempt to connec...

Page 15: ...used in navigating the loquence menu system see The Menu System page 15 3 Infrared Sensor Receives infrared IR commands from the supplied remote control Ordinarily your loquence 150i must have unobst...

Page 16: ...ute The mute key causes the volume of the amplifier to be muted or attenuated by a user customised amount see Mute page 15 6 Display The display key adjusts the display options scrolling through FULL...

Page 17: ...HT LOOP is selected or an input is set to bypass the volume control see Bypass page 21 the volume keys will have no effect 8 Source Up and Down The source keys scroll through the source inputs provid...

Page 18: ...an be customised for your conven ience see Labels page 18 Disabling an input see Enable page 19 removes it from selection by scrolling from the front panel or remote control although it is still avail...

Page 19: ...t the menu and return to the home screen or Using the front panel Press the MENU button Navigate up or down the options within a menu by rotating the interface knob left or right or using the buttons...

Page 20: ...menus Input Volume Clock Options System Input Configuration Each input on your loquence 150i integrated amplifier can be customised in several ways to enhance either the performance or the ease of us...

Page 21: ...ote control Press to scroll through the available characters Press to add the selected character to the input label and advance the label cursor Press to delete characters from the input label and mov...

Page 22: ...of any slight imbalance that may be present on a particular source component For example the finest handmade cartridges are subject to small channel imbalance problems The factory default balance tri...

Page 23: ...establish a maximum level to which the volume can be set It is particularly useful if the system is sometimes used by people who may not be as careful as you would be teenaged children come to mind Th...

Page 24: ...control for example a surround processor or receiver Care should be taken to adjust the volume control of the other component before selecting a bypassed input as the resulting volume level may be unc...

Page 25: ...lay will turn off Note If the display timeout is enabled the display will turn on when user input is detected then automatically turn off after the timeout duration has elapsed The factory default tim...

Page 26: ...o The unit info screen displays information relating to your amplifier software version serial number etc Preset The preset menu allows you to save and restore user settings for your loquence 150i int...

Page 27: ...utput devices the output to the speakers will be disconnected and the PROTECT screen is displayed The amplifier will remain in this state until it has cooled down adequately at which time the PROTECT...

Page 28: ...e mains plug is fully inserted into the wall socket and is switched on Check the mains fuse of the amplifier Check fuse in the mains plug or adaptor There is no sound Check that the source component i...

Page 29: ...___________________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________...

Page 30: ...rms Tape Outs 7 8 Vrms Frequency Response Amplifier 0dB 0 1dB from 20Hz to 20kHz 0dB 0 6dB from 10Hz to 60kHz Preamplifier 0dB 0 05dB from 20Hz to 20kHz 0dB 0 15dB from 10Hz to 60kHz Distortion THD no...

Page 31: ...Unbalanced 1 pair RCA preamp level 1 pair RCA line level Other Connections Mains Receptacle IEC C14 socket Earth Ground Terminal mini binding post IR Input 3 5mm 8 stereo jack IR Output 3 5mm 8 stereo...

Page 32: ...29 100mm 3 9 363mm 14 3 425mm 16 7...

Page 33: ......

Reviews: