![Perle S-1110DHP Installation Manual Download Page 17](http://html1.mh-extra.com/html/perle/s-1110dhp/s-1110dhp_installation-manual_1530483017.webp)
Perle Type 4 High-Power PoE PSE Ethernet Media Converter
17
Installation Guide
Enabled Normal
: When enabled, the media converter will perform
Power Sourcing Equipment (PSE) functions as per IEEE802.3af
(POE), 802.3at-2009 (POE+) or 802.3bt (PoE++) standards.
Enabled High Capacitance:
The media converter will use high
capacitance to detect whether device connected is a PD device.
Disabled
: When disabled the media converter will not perform
PSE functions.
PD Power Reset Port 1 (Switch 3)
PD Power Reset Port 2 (Switch 6)
(
dual copper models only
)
Switch Position
Mode
Up (default)
Disabled
Down
Enabled
Disabled
: When disabled, the loss of fiber link has no effect on
PSE power to the PD device.
Enabled
: When enabled, if the media converter detects loss of link
on any fiber port it will turn off PSE output power to the PD device
connected to copper port 1 and/or 2. After 2 seconds, the media
converter will restore power to the PD and the power will remain
on until one of the fiber links transitions from the link up to link
down state.
Fiber Redundancy (Switch 7)
Dual fiber models only
Switch Position
Mode
Up (default)
Disabled
Down
Enabled
Disabled
: When this feature is disabled, both fiber ports will
operate as independent ports on the media converter. Normal
media converter rules and functions will apply.
Enabled
: When this feature is enabled, fiber port 1 will be the
primary active fiber connection port and fiber port 2 will be in
standby and in an inactive state. Should a loss of link occur on
fiber port 1, fiber port 2 will be activated within 50 ms. The MAC
caching table for fiber port 2 will be cleared and the media
converter will begin to re-learn MAC address routing. See
Redundant Primary for information on link connections.