background image

Perle S 10GRT-SFP Media Converter Installation Guide                    

 

6

 

Disabled:

 The media converter will not monitor for 

fiber fault. 

 

Fiber Fault Alert Sample 
Config 

Media Converter A Configuration 

 

Link Mode 

 Standard Mode 

 

Fiber Fault Alert 

Media Converter B Configuration 

 

Link Mode

Smart Link Pass through Mode 

 

Fiber Fault Alert 

Summary of Contents for S-10GRT-SFP

Page 1: ...P N 5500432 10 Rev E Perle S 10GRT SFP Media Converter Installation Guide ...

Page 2: ...ter can use either Perle Systems or third party MSA compatible 1G 10G SFP modules See the Technical Specifications section in this guide for supported models Visit Perle s web site for the most up to date Installation guides models and specifications http www perle com Getting to know your S 10GRT SFP Media Converter Your Perle 10 GRT SFP Standalone Media Converter package consists of the followin...

Page 3: ...Perle S 10GRT SFP Media Converter Installation Guide 3 Front View ...

Page 4: ... all switches in the UP position will work for most installations These are the steps required to configure the media converter 1 Set the DIP switch settings optional 2 Insert the appropriate SFP SFP into the transceiver port 3 Connect the fiber cable 4 Connect the RJ45 copper cable DIP Switches ...

Page 5: ...tly reflected through the media converter to the other port connection If link is lost on one of the connections then the other link will be brought down by the media converter Standard In this mode the links can be brought up and down independently of each other A loss of link on either connection can occur without affecting the other connection Fiber Fault Alert Switch 2 Switch Position Mode Up ...

Page 6: ...Disabled The media converter will not monitor for fiber fault Fiber Fault Alert Sample Config Media Converter A Configuration Link Mode Standard Mode Fiber Fault Alert Media Converter B Configuration Link Mode Smart Link Pass through Mode Fiber Fault Alert ...

Page 7: ... transmitter TX Cut through Rate converting Switch 3 Switch Position Type Up default Rate converting Down Cut through Rate converting Both ports can operate at the same or different speeds Cut through Both ports need to be the same speed and set to full duplex mode Fiber Interface Loopback Switch 4 Switch Position Mode Up default Disabled Down Enabled Disabled When disabled the media converter wil...

Page 8: ...negotiate copper link parameters Manual The media converter will use the parameters as defined by Switch 6 and 7 Copper Duplex Switch 6 Switch Position Mode Up default Full Duplex Down Half Duplex Note Switch 5 must be set to manual for this setting to take affect UP The copper port will be set to Full Duplex mode Down The copper port will be set to Half Duplex mode ...

Page 9: ...ion Guide 9 Copper Speed Switch 7 Switch Position Mode Up default 100Mbps Down 10Mbps Note Switch 5 must be set to manual for this setting to take affect UP The copper port will be fixed at 100 Mbps Down The copper port will be fixed at 10 Mbps ...

Page 10: ...rt The Perle Standalone Media Converter supports SGMII on the SFP interface for the SFPs that require 1000 Mbps SGMII 1 Remove the top of the unit to access the internal jumpers 2 The SGMII jumper is located on the outer edge at the midpoint of the card P3 Jumper Pin 1 and Pin 2 ...

Page 11: ...rter LEDs statuses PWR Power Test Green On Power is on and the module is in normal operation mode Green blinking slowly the module is in test or loopback mode Red Solid Hardware error detected See PWR Red LED Errors Red Blinking quickly Error detected See LK1 LK Errors LK1 Port 1 Activity On Fiber link present ...

Page 12: ...nt SP Port 2 Speed Green 2 5G 10G Yellow 100M 1G Off 10M LK Port 2 Activity On Copper link present Blinking quickly Copper link present and receiving data Blinking slowly The copper link has been taken down as a result of Smart Link Pass Through Off No copper link present LK1 LK Error Codes LK1 LK Meaning Off Off Incompatible SFP SFP On On Internal Error Off On Mismatch in Cut though mode On Off S...

Page 13: ...d module has been exceeded Off Off Internal Hardware Grounding the Chassis If your installation requires additional grounding follow this procedure Grounding the chassis requires the following items One grounding lug not provided One 18 12 AWG wire not provided Note For your safety when installing this equipment always ensure that the chassis ground connection is installed first and disconnected l...

Page 14: ...GRT SFP Media Converter Installation Guide 14 Attaching the Grounding Lug 1 Attach the grounding lug to one end of an 18 12 AWG wire 2 Attach the grounding lug to the chassis and secure with the grounding screw s ...

Page 15: ...cord through the opening in the power cord relief clip 2 Attach the power cord relief clip to the chassis and secure with the provided screw Installing the SFP Fiber Module 1 Locate appropriate fiber module and insert into the opening 2 Ensure the SFP SFP module is properly seated 3 Proceed with fiber cable connection ...

Page 16: ...Duplex Fiber Cable 1 Locate a 1000 10GBase X compliant duplex 2 strands fiber cable with appropriate connectors 2 Connect the fiber cables from the SFP SFP to the other Media Converter switch fiber device ensuring that the RX and TX are reversed crossed at the opposite end ...

Page 17: ...t the fiber cable from the SFP SFP to the other media converter switch fiber device Installing the Copper Cable 1 Locate 10 100 1000 10GBase T compliant copper cables with male RJ45 connectors installed at both ends 2 Connect the RJ45 cable between the media converter and the device Note The Perle Media Converter supports Auto MDIX which allows a straight through or cross over Ethernet cable ...

Page 18: ...perating above its specified maximum operating temperature the S 10GRT SFP will reduce the power to the module The S 10GRT will continue to monitor the operating temperature of the unit until the temperature is below the maximum operating temperature and then the S 10GRT SFP will return the module to normal operating Loopback Mode Perle Standalone media converters can be put into loopback mode for...

Page 19: ...le Fiber Transceiver IEEE 802 3ae 10G Base R 10 Gigabit SFP slot support 10GBase R Standard SFP Power level 1 1 watt and level 2 1 5 watts as per SFP 8431 Operating Temperature 0 C 50 C 32 F 122 F Storage Temperature 25 C 70 C 13 F 158 F Operating Humidity 5 to 90 non condensing Storage Humidity 5 to 95 non condensing Operating Altitude Up to 3 048 m 10 000 ft Weight 0 36kg 0 79 lbs ...

Page 20: ...Fiber pluggable transceivers IEEE 802 3as compliant 10GBase SR 10GBase LMR 10GBase LR 10GBase ER 10GBase ZR CWDM DWDMBase Supported 10 Gigabit Copper pluggable transceivers SFP Direct Attach Cable DAC Also known as Twinax 10GBase CU 10GSFP Cu 10GBase CX1 10GBase CR1 Note Passive and Active cable types are supported Supported Gigabit Fiber SFP s 1000Base SX 1000Base LX LH 1000Base EX 1000Base ZX 10...

Page 21: ...50 125 microns or 62 5 125 microns SM 9 125 microns Copper Cable Requirements Category 6A for 10G speeds 5 5e used for speeds under 10G Straight through or Ethernet crossover Note Please refer the product page on the Perle website for the most up to date specifications http www perle com ...

Page 22: ...o the transceiver port Ensure that the copper cabling RJ45 meets Ethernet copper cabling requirements No connectivity Set all DIP switches to the Up position Loopback Mode The media converter can be put into Loopback mode for diagnosis purposes A packet generator and analyzer must be used to generate and capture the packets in this mode ...

Page 23: ...hich case the user will be required to correct the interference at his her own expense EN 55032 Class A WARNING This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures EN 55024 Class A Contacting Technical Support Contact information for the Perle Technical Assistance Center PTAC can be found at ...

Reviews: