background image

Gigabit Fiber to Fiber Media Converter Module – Installation Guide

    

Overview 

This document contains instructions necessary for the installation 
and operation of the Perle Gigabit Fiber to Fiber Media Converter 
Module(s) that are used in conjunction with a Perle MCR chassis. 
The C-1000MM media converters are unmanaged modules, and 
the CM-1000MM are the managed converter modules. These 
products allow dissimilar 1000Base-X fiber interfaces to connect to 
one another. For information on the management options of the 
CM-1000MM module, refer to the MCR-MGT Module User’s 
Guide. 

These are the fiber to fiber conversion models: 

  Multimode to Multimode  (MM) 

  Multimode to Single Mode  (SM)  

  Multimode to Single Mode Single Strand  (MM) 

The first fiber port will be multimode (MM) and the second fiber 
port can be either single mode (SM) or multimode (MM) depending 
on the model selected. They can operate over different 
wavelengths and distances. (See tables below). 

Fiber port 1 – MM1 

Model  

Connector 

Mode  

Distance  

Wavelength 
(TX/RX)
 

All models

 

SC/ST/LC 

MM.

 

550 m/1804 ft. 

850 nm 

Fiber port 2 – MM2/SM2 

Model  

Connector 

Mode  

Distance 

Wavelength 
(TX/RX)
 

C-1000MM-M2xx05 
CM-1000MM-M2xx05

 

SC/ST/LC 

MM

 

550 m/1804 ft. 

 

850 nm 

C-1000MM-M2xx2 
CM-1000MM-M2xx2

 

SC/ST/LC 

MM

 

2 km/1.2 mi. 

 

1310 nm 

C-1000MM-S2xx10 
CM-1000MM-S2xx10

 

SC/ST/LC 

SM

 

10 km/6.2 mi. 

 

1310 nm 

C-1000MM-S2xx40 
CM-1000MM-S2xx40

 

SC/ST/LC 

SM

 

40 km/24.9 mi. 

 

1310 nm 

C-1000MM-S2xx70 
CM-1000MM-S2xx70

 

SC/ST/LC 

SM

 

70 km/43.5 mi. 

 

1550 nm 

C-1000MM-S2xx120 
CM-1000MM-S2xx120

 

SC/ST/LC 

SM

 

120 km/74.6 mi. 

 

1550 nm 

Summary of Contents for C-1000MM-M2SC05

Page 1: ...P N 5500315 11 Perle Gigabit Fiber to Fiber Media Converter Module Installation Guide C 1000MM XXXXXX Unmanaged Module CM 1000MM XXXXXX Managed Module...

Page 2: ...o Single Mode SM Multimode to Single Mode Single Strand MM The first fiber port will be multimode MM and the second fiber port can be either single mode SM or multimode MM depending on the model selec...

Page 3: ...km 12 4 mi 1490 1310 nm C 1000MM S1SC40U CM 1000MM S1SC40U SC SM 40 km 25 mi 1310 1490 nm C 1000MM S1SC40D CM 1000MM S1SC40D SC SM 40 km 25 mi 1490 1310 nm C 1000MM S1SC80U CM 1000MM S1SC80U SC SM 80...

Page 4: ...3 Insert the Media Converter Module into the chassis 4 Connect the fiber cables Auto Config Jumper CM 1000MM only The Auto Config jumper is J5 Refer to the diagram below for labelling Auto Pin 2 and P...

Page 5: ...nverter will negotiate fiber parameters on both MM1 and MM2 SM2 fiber ports This will ensure the most optimal connection parameters will be in effect If connecting to another Perle media converter thi...

Page 6: ...Up default Enabled Down Disabled Enabled If the media converter module detects a loss of fiber signal on the fiber receiver the media module will immediately disable its fiber transmitter signal on t...

Page 7: ...verter B Configuration Link Mode Smart Link Pass Through Mode Fiber Fault Alert Sequence of Events 1 Media Converter A loses fiber connection RX on MM2 SM2 2 Media Converter A disables the transmitter...

Page 8: ...ive RX fiber connection is looped back to the transmit TX fiber connection Note Only one fiber interface can be in loopback at a time Remote Loopback Fiber 2 Switch 5 Switch Position Mode Up default D...

Page 9: ...slot opening 3 Set the jumpers and DIP switches on the Media Converter Module to the desired operating mode optional 4 Locate the top and bottom alignment guides inside the MCR Chassis 5 Using the mo...

Page 10: ...te and secure the screw Installing the Duplex Fiber Cable 1 Locate a 1000Base X compliant duplex 2 strands fiber cable with appropriate connectors 2 Connect the fiber cables from one Converter to the...

Page 11: ...n loopback mode Blinking quickly the module has a hardware error LK1 MM1 Fiber Link10 Activity On Fiber link present Blinking quickly Fiber link present and receiving data Blinking slowly The fiber li...

Page 12: ...he UP position these methods are recommended for troubleshooting Method 1 1 Turn off Fiber Negotiation SW1 Down on both media converters Leave all other switches UP 2 Connect the near end device to po...

Page 13: ...de Wave length nm TX Power dB RX Power dB Budget dB C 1000MM M2SC05 CM 1000MM M2SC05 MM TX 850 RX 850 Min 9 5 Max 4 Min 17 Max 3 7 5 Model Mode Wave length nm TX Power dB RX Power dB Budget dB C 1000M...

Page 14: ...x 3 Min 20 Max 3 11 C 1000MM S1SC20U CM 1000MM S1SC20U SM TX 1310 RX 1490 Min 8 Max 3 Min 22 Max 3 14 C 1000MM S1SC20D CM 1000MM S1SC20D SM TX 1490 RX 1310 Min 8 Max 3 Min 22 Max 3 14 C 1000MM S1SC40U...

Page 15: ...in which case the user will be required to correct the interference at his her own expense EN 55022 Class A WARNING This is a Class A product In a domestic environment this product may cause radio in...

Page 16: ...e found at http www perle com support_services warranty shtml Contacting Technical Support Contact information for the Perle Technical Assistance Center PTAC can be found at the link below A Technical...