IDS-305F Hardware Installation Guide
Appendix A - Technical Specifications
This appendix provides the technical specification for the IDS-305F(-XT ) switches.
Specifications
Dual input terminal block
9.6 to 60 VDC
SELV, limited-energy per 61010-1 cl.9.4
Models
Rated Voltage Max. Rated
(CLASS 2) Current
Alarm Relay Output
IDS - 305F(-XT)
9.6 Vdc 0.350A
1.0A at 24Vdc
0.5A at 48Vdc
Rated Cable Temperatures
IDS-305F
IDS-305F(-XT)
>74°C
>90°C
Overload Current Protection
Fuse
Reverse Polarity Protection
Yes
Weight
610 grams
Interfaces
10/100/1000Base-T (RJ45)
Industry standard RJ-45 connector
Fiber 100Base-X
Fixed Fiber (SC/ST) - varies by model
Console
RJ-45 connector
LED Indicators
PWR - Power Inputs
SYS - System Status
ALR - Alarm
BC - For Future Use
RM - For Future Use
5 - Fiber Port Link/Activity
Ports 1-4 G/Y - Link/Activity/Speed
Reset/FS (Fast Setup) switch
Inset on front panel
Terminal Block
Rated at
105°C (221°F)
Environmental
Operating Temperature
Commercial Models (IDS-305F)
Industrial Models (IDS-305F-XT)
-
10°C to 60°C (14°F to 140°F)
-
10°C
≤
TAMB
≤
to 60°C
-40°C to 75°C (-40°F to 167°F)
-
40°C
≤
TAMB
≤
75°C
S
torage Temperature
Commercial Models (IDS-305F)
Industrial Models (IDS-305F-XT)
-25°C to 75°C (-13°F to 167°F)
-40
°C C to 85°C (-40°F to 185°F)
Operating Humidity
5% to 90% non-condensing
Storage Humidity
5% to 95% non-condensing
Operating Altitude
Up to 3,048 m (10,000 ft)