with the lamp) must be submitted within 20 days of the lamp failure along with the
failed lamp packaged in its original shipping container. Call Perko at 1-(305)-621-
7525 to obtain an RGA number. Then ship failed lamps to Perko prepaid.
5.
Any credit due as a result of warranty evaluation of returned lamps will be issued
only to the original authorized Perko purchasing dealer/distributor of the lamp.
6.
This warranty is limited to the lamp only. Any further claim for indemnification is
excluded.
7.
Perko will provide a lamp purchase credit for any xenon lamp which fails prema-
turely due to any defect in material or workmanship provided that it has been
operated on proper auxiliary equipment at no higher than the “Recommended
Operation” level (shown below) and has not been physically or electrically mis-
used or misapplied. The lamp purchase credit shall be based on accumulated
hours of operation.
Figure
Rated
Recommended
Number
Wattage
Operation
Current Range
95630000
300
15A @20V
12A to 16A
95650000
500
30A @15V
20A to 30A
95680000
800
37A @19V
30A to 45A
95600100
1,000
50A @20V
30A to 55A
95660160
1,600
65A @24V
50A to 70A
INSTRUCTIONS FOR INSTALLING
XENON LAMPS
INSTALLATION OF LAMPS
Disconnect the main connector from the AC Power Supply and assure that all
breakers are off before opening the searchlight housing (front glass).
INSTRUCTIONS FOR USING XENON LAMPS
The contact surface of all electrical connections must be free of foreign bodies, cor-
rosion and scorch marks to insure good conductivity. Check regularly to assure that all
clamps and cables are firmly in place, and especially after fitting the lamp.
The lamp supports must not transfer any mechanical stress to the lamp, either dur-
ing installation or during operation (due to thermal expansion).
Insert lamp (with protective cover still in place) into the lamp supporting fixtures
28
7-2
Summary of Contents for 9304
Page 2: ......