Gear teeth backlash
To check
Operation 6-12
Measure the clearances one at a time with a feeler gauge at each of the locations shown. If the measurement
is outside the service limit fit new gears.
Engine
Timing gear tolerances mm (in)
Standard
Service limit
All models
0,08 (0.0032)
0,25 (0.0098)