MAINTENANCE PROCEDURES
30
4012/16 Gas, February 1998
TURBOCHARGERS
If the engine has been overhauled and a
filter joint fitted to the turbocharger oil feed,
this should now be removed and replaced
with
the
standard
joint.
See
Service
Bulletin 301 (Revised) and 1
.
FOR ENGINES OPERATING ON BIOGAS,
LANDFILL GAS, ETC.
SPARK PLUGS
Clean and reset gaps as described
in
Section N9
of the
Workshop manual
.
ENGINE OIL AND SPIN-ON FILTERS,
ALSO CENTRIFUGAL OIL FILTER
(WHERE FITTED)
Change engine oil and disposable filters
(see
page 34
)
clean centrifugal filter
(see
page 33
)
.
ENGINE ALTERNATOR DRIVE BELT
Remove the small mesh guard (1) around
the alternator. The toothed belt used to drive
the alternator relies on tooth engagement to
transmit
to
load.
It
does
not
require
preloading, however a slight initial tension to
ensure that the belt fits snugly round the
pulleys is desirable. Using light pressure
midway between the two pulleys a total
deflection of 1.5 mm (
1
/
16
”) is satisfactory
(see
Fig. 17
). Refit the guard.
SPARK PLUGS
Reset the plug gap as described in
Section
N9 and N12
of the
Workshop Manual
.
ENGINE OIL AND FILTERS
On completion of the first 500 hours
running, change the engine oil and
filters.
DISCONNECTING
BATTERIES OR ANY
OTHER MEANS OF STARTING.
WARNING
Fig. 17
Summary of Contents for 4012TESI Series
Page 1: ...TSL4187E Issue 1 February 1998 User s Handbook Perkins 4012 and 4016 Gas 4012TESI 4016TESI...
Page 7: ...4012TESI MINNOX 4012TESI MINNOX...
Page 8: ...4016TESI MINNOX 4016TESI MINNOX...
Page 49: ...4012 4016 GAS ENGINES FAULT TRACING CHART 4012 16 Gas February 1998 45 Fig 34...