OPERATING INSTRUCTIONS
26
4012/16 Gas, February 1998
4.
Stopping
4.1)
Remove load, run for 3 to 5
minutes to reduce combustion
system
temperatures
and
localised boiling of coolant and
to prevent oil carburizing in the
turbocharger bearing housing.
4.2)
Stop engine by de-energising
gas
solenoid
valves
and
governor.
DO NOT press the
red
stop
button
for
normal
stopping
procedure.
If
the
ignition
is
switched
off
the
system will be left full of gas, and
must be purged.
Excessive running of the engine at rated
speed no load results in a high depression in
the cylinders, leading to high oil consumption
and a build up of deposits on spark plugs,
valves and pistons.
DO NOT RUN THE
ENGINE
EXCESSIVELY AT RATED SPEED ON
NO LOAD. IF THE ENGINE IS NOT
BEING USED, SHUT IT DOWN.
WARNING