SEBU8337
65
Maintenance Section
Engine Crankcase Breather - Replace
g01404604
Illustration 29
Typical example
2.
Unlatch the clips (2) that secure the
fi
lter bowl (6).
g01404613
Illustration 30
Typical example
3.
Remove the
fi
lter bowl and remove the
fi
lter
element (5). Remove the O ring seal (4) with the
fi
lter element.
4.
Remove the main O ring seal (3). Clean the
fi
lter
bowl.
5.
Install a new O ring seal (3). Install the new O ring
seal (4) on the new
fi
lter element (5). Install the
fi
lter element into the
fi
lter bowl (6).
6.
Align the
fi
lter element and the
fi
lter bowl. Install
the
fi
lter bowl to the top of the breather. Connect
the drain (1).