Illustration 37
g01348394
Typical example
Adjustment of the cover will change the clearance
(gap) between the edge of the cover and the tip of
the fan blade. Ensure that the cover is centralized to
the fan.
The maximum clearance is 15 mm (0.591 inch). The
minimum clearance is 10 mm (0.394 inch).
i07766418
Fuel
Control
Linkage
-
Check/
Lubricate
Do
not
work
on
the
engine
unless
the
instructions
and
warnings
are
understood.
Refer
to
the
safety
section
in
this
Operation
and
Maintenance
Manual
for
more
information.
Perkins recommends a scheduled inspection of the
fuel control linkage for the fuel injection pump for
loose components and free movement of the linkage
.The fuel control linkage for the fuel injection pump
and solenoid ball joint plunger is lubricated at defined
intervals.
To maximize the engine performance, check the fuel
control linkage for wear, secure installation, and
unrestricted movement of the mechanism. Ensure
that the fuel control linkage is sufficiently lubricated.
64