Illustration 16
g00939480
Cylinder and valve location
(A) Inlet valve
(B) Exhaust valve
Table 1
Engine Specifications for the 1106AA-70T, and 1106AA-70TA
engines
Operating Range (rpm)
1500 to 1575
1800 to 1890
Number of Cylinders
6 In-Line
Bore
105 mm (4.13385 inch)
Stroke
135 mm (5.31495 inch)
Aspiration
Turbocharged
Turbocharged aftercooled
Compression Ratio
16:1
Displacement
7.01 L (427.78 cubic inch)
Firing Order
1-5-3-6-2-4
Rotation (flywheel end)
Counterclockwise
Valve Lash Setting (Inlet)
0.35 mm (0.013 inch)
Valve Lash Setting (Exhaust)
0.45 mm (0.018 inch)
(1)
For fixed speed applications with a frequency of 50Hz, the op-
erating rpm depends on the engine rating, and the application.
(2)
For fixed speed applications with a frequency of 60Hz, the op-
erating rpm depends on the engine rating, and the application.
Engine Cooling and Lubrication
The cooling system consists of the following
components:
• Gear-driven centrifugal water pump
• Water temperature regulator which regulates the
engine coolant temperature
• Gear-driven rotor type oil pump
• Oil cooler
The engine lubricating oil is supplied by a rotor type
oil pump. The engine lubricating oil is cooled and the
engine lubricating oil is filtered. The bypass valve can
provide unrestricted flow of lubrication oil to the
engine if the oil filter element should become
plugged.
Engine efficiency, efficiency of emission controls, and
engine performance depend on adherence to proper
operation and maintenance recommendations.
Engine performance and efficiency also depend on
the use of recommended fuels, lubrication oils, and
coolants. Refer to Operation and Maintenance
Manual, “Maintenance Interval Schedule” for more
information on maintenance items.
M0106585