performaxopeners.com Customer Service: 1-877-436-4402
15
Photos eyes
should be no
more than 6
inches (15.2 cm)
above the floor.
CONNECTING PHOTO EYE SAFETY SYSTEM
Look in the box for:
Mount photo eyes using #12 x 1-1/4" screws provided.
Run wire to power head. Use insulated staples
to secure photo eye wires to wall and ceiling.
Take care not to puncture the wires while
securing staples.
Cut and discard excess wire. Use small flat head screwdriver to
push in grey tab on the terminal block located on the rear panel
of the power head. Insert 1/2 inch (1.2 cm) of the wire into the
terminal while pushing in the tab.
* VERY IMPORTANT! *
Strip 7/16 inch (1 cm) of insulation
from the end of the wire.
Each pair of terminals MUST be
connected with one white wire and
one striped wire (non-polarized) from
the SAME photo eye.
Floor mounting
(concrete anchors
not provided)
To prevent SERIOUS INJURY or DEATH from
electrocution:
• Power MUST NOT be connected until instructed.
• The garage door opener will not operate until the
photo eye safety system is properly connected and
aligned.
• Install the photo eye safety system NO higher than
6 inches (15 cm) above the floor.
• No part of garage door or other objects should
obstruct the photo eye safety system during door-
closing.
4 x Screws
#12 x 1-1/4"
7/16 inch
(1 cm)
Alternative mounting location:
Door track / wall mounting. Photo
eyes should be no more that 6
inches (15.2 cm) above the floor.
Insulated Staples
Photo Eyes
WARNING