First Time Operation:

• Before you start using this unit, please check there is no transportation damage, should there be any, please

do not use the device and contact your dealer immediately.

• Put the smoke machine on a flat stable surface. Make sure no one can put any body part close to the heater

output.

• Unscrew the Lid on the fluid bottle, fill up with a suitable fog liquid, make sure not to over fill. Then screw

the plastic cap back on. Make sure the tank never runs dry during operation.

• Connect the PFX400S LED to a suitable mains supply.

• Allow the machine to warm up for about 3 minutes.

• The ready indicator light will light up, on the wired remote.

• The smoke machine is now ready to use.

• Press the switch to ON on the wired remote to operate.

• If the ready light goes out, the smoke machine needs to reheat before it will work again.

Overhead Rigging:

The installation must be carried out by a qualified engineer only. Improper installation can result in injuries or

damage to property. Overhead rigging requires experience. Working loads should be a heard to, certified

materials should be used. The installed device should be regularly inspected for safety.

•  Make sure the working area is clear from people and obstructions during rigging, de-rigging and servicing.

•  Locate the smoke machine in a well ventilated area away from flammable materials and liquids. The smoke

machine needs to be 50cm away from surrounding walls and fixtures.

•  The smoke machine should be installed out of reach of people and not where people are seated, walking or

standing.

•  When mounting make sure the installation point can take the weight.

•  Make sure a safety chain or wire is always used and can take the weight of the smoke machine. This is a

secondary support, never rely on this for the primary support.

•  The smoke machine should be well fixed and free from swinging.

•  Do not cover any ventilation holes.

•  Turn of the supply power off when the machine is not in use for an event.

•  The operator must make sure the smoke machine has been installed correctly to all the necessary

guidelines before each use. The installation should be inspected every 6 months.

Maintenance:

• Do not allow liquid to become contaminated. Always replace the cap on the liquid container immediately

after filling.  

• After every 40 hours of operation, or if the unit is not to be used for one month, It is recommended to run a

cleaning solution of 20% clear vinegar and 80% distilled water through the system to prevent clogging in the

heater.  This should be carried out in a well-ventilated room. 

• Always empty the fluid and water tanks after every use. Use a dry cloth to wipe down the outside of the

smoke machine. Make sure the power cable is disconnected from the mains supply.

• The mains cable must be in impeccable condition and should be replaced if a small defect is detected. All

other maintenance should be carried out by a qualified engineer.

Summary of Contents for Mini LED Fog 400

Page 1: ... NOT OPEN RISQUE D ELECTROCUTION NE PAS OUVRIR STROMSCHLAGGEFAHR NICHT OFFNEN In Compliance with the following directives RoHS Directive 2002 95 EU and WEEE directive 2002 96 EU If this product is no longer functional or reached the end of its usable life please take it to an approved recycling plant ...

Page 2: ...o responsibility for injury or damage caused as a result of not following the manual provided Protection from Electric Shock Only connect this unit to a mains socket with suitable trip and RCD protection To disconnect from the mains socket always remove by the mains plug Do not attempt to remove by pulling the mains cable Disconnect the unit from the mains supply before cleaning Cleaning should be...

Page 3: ...ately remove all liquid and return in original packing to your dealer Danger of Injury or Burns For operation by adults only ensure installation is away from the reach of children Never leave the machine running unattended Avoid all contact with the heater Never aim the nozzle directly at people Use only in a well ventilated area do not cover the machine vents In order to guarantee adequate ventil...

Page 4: ... mounting to truss always use a safety wire as secondary support 4 Liquid Level Fluid level reading do not overfill 5 Wire Controller Is connected to the wired remote control 6 Power Switch Used to turn the smoke machine on and off 7 Fuse Holder If this blows once replace with the correct size fuse if it blows again there may be a problem with the machine seek professional help from an engineer 8 ...

Page 5: ...and liquids The smoke machine needs to be 50cm away from surrounding walls and fixtures The smoke machine should be installed out of reach of people and not where people are seated walking or standing When mounting make sure the installation point can take the weight Make sure a safety chain or wire is always used and can take the weight of the smoke machine This is a secondary support never rely ...

Reviews: