INSTALLATION INSTRUCTIONS (CONTINUED)
Water drainage:
- During dehumidifying modes, remove the drain
plug from the back of the unit and attach 3/4” vinyl
tube included with the unit (5/8” outer diameter).
For the models without drain connector, just
attach the drain hose to the hole. Place the open
end of the hose directly over the drain area in
your basement floor. See Fig. 20 & 21.
- When the water level of the bottom tray reaches
a predetermined level,
the unit beeps 8 times and
the digital display area shows "P1". At this time
the air conditioning/dehumidification process will
immediately stop. However, the fan motor will
continue to operate (this is normal).
Carefully move the unit to a drain location,
remove the bottom drain plug and let the
water drain away (Fig. 22). Restart the machine
until the "P1" symbol disappears. If the P1 symbol
will not clear after following the above instructions
and waiting a few minutes after restarting
the machine, call customer service.
NOTE: Be sure to reinstall the bottom drain plug
before using the unit.