background image

5

Please read ALL instructions before installing. It is 

recommended that two people install this product. 

If a new electrical outlet is required, have the outlet 

installed by a qualified electrician before installing the 

air conditioning unit.

Window Sash Seal

Top Angle

Foam Gasket

Side Retainer

Locknut

Safety Lock and  

3/4

 (or 1/2

)  

Long Hex Head Screw

1/2

 Long

 

Screw and

 

Locknuts

Washer Head 

Locking Screw

Seal Bottom 

Rail to Unit

Frame  

Assembly  

(Left)

Frame Assembly 

(Right)

3/4

 Long  

Flat Head  

Bolt

Sill Angle 

Bracket

Window Support 

Bracket

FIG. A

SASH

SASH

19

 MIN.

19

 MIN.

1/2

 MIN.

1/2

 MIN.

1/2

 MIN.

Board 

thickness 

as required 

along entire 

stool. Fasten 

with 2 Nails 

or Screws.

Storm window 

frame or other 

obstruction

Storm window 

frame or other 

obstruction

FIG. B

FIG. C

PRELIMINARY INSTRUCTIONS

Do the following before installing the unit. (See 

illustrations on left.)
Check dimensions of your unit to determine proper 

window dimensions:

Unit Height:

17 

5

/

8

or 18 

5

/

8

Unit Width:

23 

5

/

8

or 26 

1

/

2

Min. Window Height: 18 

1

/

2

or 19 

1

/

2

Min. Window Width: 28

or 31

Max. Window Width: 40 

1

/

2

or 42

1. CHECK WINDOW OPENING SIZE

 — The  mounting  parts 

furnished with this air conditioner are made to install  

in a wooden sill, double-hung window. The standard 

parts are for window dimensions listed above. Open 

sash to a minimum of 19 in. (483 mm). See Fig. B .

2. CHECK CONDITION OF WINDOW 

— All wood parts of 

window MUST be in good shape and able to firmly 

hold the needed screws. If not, make repairs before 

installing unit.

3. CHECK YOUR STORM WINDOWS 

— If your storm 

window frame does not allow the clearance required, 

correct by adding a piece of wood, as shown in 

Fig. C, or by removing storm window while room air 

conditioner is being installed.

4. CHECK FOR ANYTHING THAT COULD BLOCK AIRFLOW 

  

Check area outside of window for things such as 

shrubs, trees, or awnings. Inside, be sure furniture, 

drapes, or blinds will not stop proper airflow.

5. CHECK THE AVAILABLE ELECTRICAL SERVICE

 — Power 

supply MUST be the same as that shown on the 

unit serial nameplate. Power cord is 48 inches long. 

Be sure you have an outlet near. DO NOT use an 

extension cord.

6. CAREFULLY UNPACK THE AIR CONDITIONER 

— Remove 

all packaging material. Cover the floor during 

installation to prevent damage. Two people should be 

used to move and install unit.

Summary of Contents for 4PAC15000

Page 1: ...WINDOW AIR CONDITIONER FOR MODEL 4PAC15000 4PAC18000 4PAC25000 Before using your air conditioner please read this manual carefully and keep it for future reference along with your receipt USER MANUAL...

Page 2: ...___________________________ Purchase Date _____________________________________ Store Purchased ______________________________________ Installation Date ____________________________________ Installati...

Page 3: ...ir or maintenance of this unit If necessary contact an installer for installation of this unit The air conditioner is not intended for use by young children without supervision Young children should b...

Page 4: ...the unit Failure to do so may cause fire and electric shock DO NOT use the socket if it is loose or damaged Doing so may cause fire and electric shock DO NOT open the unit during operation Doing so m...

Page 5: ...d of time unplug or turn OFF main power switch Leaving power on may cause unit failure or fire Do not place obstacles around air inlets or inside of air outlet Obstacles may cause appliance failure or...

Page 6: ...sure the air conditioner has been securely and correctly installed according to the installation instructions in this manual Save this manual for possible future use in removing or installing this un...

Page 7: ...Do not under any circumstances cut or remove the third ground prong from the power cord Do not change the plug on the power cord of the air conditioner Aluminum house wiring may present special proble...

Page 8: ...or 31 Max Window Width 401 2 or 42 1 CHECK WINDOW OPENING SIZE The mounting parts furnished with this air conditioner are made to install in a wooden sill double hung window The standard parts are for...

Page 9: ...ing screws from top of unit See Fig 5 8 Hold the cabinet while pulling on the base handle and carefully remove the unit 9 Add two foam inserts to holes in top of cabinet where shipping screws were rem...

Page 10: ...panel frame into channel in the top angle and bottom rail Do this on both sides 4 Insert washer head locking 7 16 screws 2 into holes in top leg of filler panel frame See step 6 on next page Do not to...

Page 11: ...adjust slope Fig 14 FIG 14 FIG 15A Mark About 11 2 to 15 8 Window Sash Side Louvers Sill Angle Bracket Window Sill Measure from the cabinet edge 5 FIG 15B Right Left Locknut 1 2 Log Screws and Locknut...

Page 12: ...ne 3 4 or 1 2 long hex head screw A 3 4 or 1 2 long hex head screw B Left hand Window Filler Panel Top Leg C Window channel A 3 4 or 1 2 long hex head screw A A B C Window Sash Weather Seals FIG 18A F...

Page 13: ...width in Step 10 1 Cut the insulation panel along the line Fig 21 or STEP 10 3 Slide the insulation panel you just cut into the accordion panel curtain The side of the insulation panel with the patte...

Page 14: ...ill be installed by sounding wall or by magnetically finding nails 2 Cut or knock out a hole on each side of center stud 3 Measure between inside edges of every other stud as shown in Fig 1 NOTE Caref...

Page 15: ...de If after proper installation condensation does not drain from the overflow drain hole during normal use adjust slope MASONRY CONSTRUCTION 1 Cut or build a wall opening in the masonry wall similar t...

Page 16: ...all of its functions Afterwards follow the symbol for the functions you desire BEFORE operating the unit This unit can be controlled by the unit control or the remote control Remote Signal Receptor TO...

Page 17: ...m AUTO COOL DRY HEAT for units with heating function and FAN The indicator light will be illuminated and remain on once the mode is selected The unit will automatically initiate the Energy Saver funct...

Page 18: ...rection is obtained Move the levers from side to side until the desired Left Right direction is obtained ADDITIONAL THINGS YOU SHOULD KNOW The Cool circuit has an automatic 3 minute time delayed start...

Page 19: ...m the filter clean NOTE Never use hot water over 104 F 40 C to clean the air filter Never attempt to operate the unit without the air filter CABINET CLEANING Be sure to unplug the air conditioner to p...

Page 20: ...he coil set to FAN only mode Then set temperature to a higher setting AIR CONDITIONER CYCLING ON AND OFF TOO FREQUENTLY OR NOT ENOUGH Be sure unit is not too large or too small for the area of the roo...

Page 21: ......

Page 22: ......

Page 23: ...The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details...

Page 24: ...Line Rd Suite 878 Dallas TX 75254 Distributed by 844 4PA AIRE 844 472 2473 www perfectaire us Specification and performance data is subject to change without notice Printed in China PA User4PAC15000_4...

Reviews: