3

IMPORTANT SAFETY INSTRUCTIONS

 NOTE:

The power supply cord with this air 

conditioner contains a current detection 

device designed to reduce the risk 

of fire. Please refer to the section 

“Operation of Current Device” (below) 

for details. In the event that the power 

supply cord is damaged, it cannot be 

repaired. It must be replaced by an 

authorized repair technician with a cord 

from the Product Manufacturer.

WARNING

Avoid fire hazards or electric shock.  

DO NOT

 use an extension cord or an 

adapter plug. 

DO NOT

 remove any prong 

from the power cord.

OPERATION OF  

CURRENT DEVICE:

The power supply cord contains a 

current device that senses damage 

to the power cord. To test your power 

supply cord, do the following: 

1.  Plug in the air conditioner.

2.  The power supply cord will have 

TWO buttons on the plug head. Press 

the TEST button. You will notice a 

click as the RESET button pops out.

3.  Press the RESET button. Again, 

you will notice a click as the button 

engages.

4.  The power supply cord is now 

supplying electricity to the unit. (On 

some products this is also indicated 

by a light on the plug head.)

WARNING

FOR YOUR SAFETY: Do not store or use gasoline or other flammable 

vapors and liquids in the vicinity of this or any other appliances.

WARNING - PREVENT ACCIDENTS

To reduce the risk of fire, electrical shock, or injury to persons when using 

your air conditioner, follow basic precautions, including the following: 

●  Be sure the electrical service is adequate for the model you have 

chosen. This information can be found on the serial plate, which is 

located on the side of the cabinet and behind the grille.

●  If the air conditioner is to be installed in a window, you will probably 

want to clean both sides of the glass first. If the window is a triple-

track type with a screen panel included, remove the screen completely 

before installation.

●  Be sure the air conditioner has been securely and correctly installed 

according to the installation instructions in this manual.

●  Save this manual for possible future use in removing or installing this unit.

●  When handling the air conditioner, be careful to avoid cuts from sharp 

metal fins on front and rear coils.

WARNING - ELECTRICAL INFORMATION

The complete electrical rating of your new room air conditioner is  

stated on the serial plate. Refer to the rating when checking the  

electrical requirements.

●  Be sure the air conditioner is properly grounded. To minimize shock 

and fire hazards, proper grounding is important. The power cord is 

equipped with a three-prong grounding plug for protection against 

shock hazards. 

●  Your air conditioner must be used in a properly grounded wall 

receptacle. If the wall receptacle you intend to use is not adequately 

grounded or protected by a time delay fuse or circuit breaker, have a 

qualified electrician install the proper receptacle.

●  Ensure the receptacle is accessible after the unit installation.

● 

DO NOT

 run air conditioner without side protective cover in place. This 

could result in mechanical damage within the air conditioner.

● 

DO NOT

 use an extension cord or an adapter plug.

 NOTE:

DO NOT

 use the plug to turn the unit on or off.

●  Always make sure the RESET button is pushed in for correct operation.

●  The power supply must be replaced if it fails reset when either the TEST 

button is pushed or it cannot be reset.

●  If power supply cord is damaged, it cannot be repaired. Please call 

Consumer Services at 844-472-2473 to assist with replacement.

NOTE:

 This air conditioner is designed to be operated under the

following conditions:

Cooling 

Operation

Outdoor Temp:

64 – 109°F/18 – 43°C

(64 – 125°F/18 – 52°C for special tropical models)

Indoor Temp:

62 – 90°F/17 – 32°C

Heating 

Operation

Outdoor Temp:

23 – 76°F/-5 – 24°C

Indoor Temp:

32 – 80°F/0 – 27°C

Performance may be reduced outside of these operating temperatures.

Grounding Type

Wall Receptacle

Do not, under any 

circumstances, cut, 

remove, or bypass the 

ground prong.

Power supply cord  

with 3-prong grounding 

plug and current 

detection device

Summary of Contents for 3PATW14002

Page 1: ...TWH10002 WITH ELECTRIC HEATER 3PATWH12002 WITH ELECTRIC HEATER 3PATWH14002 WITH ELECTRIC HEATER 3PATW14002 Before using your air conditioner please read this manual carefully and keep it for future re...

Page 2: ...___________________________ Purchase Date _____________________________________ Store Purchased ______________________________________ Installation Date ____________________________________ Installati...

Page 3: ...for installation of this unit if necessary The air conditioner is not intended for use by young children without adult supervision Young children should be supervised to ensure that they do not play w...

Page 4: ...m the unit Failure to do so may cause fire and electric shock DO NOT use the socket if it is loose or damaged Doing so may cause fire and electric shock DO NOT open the unit during operation Doing so...

Page 5: ...of time unplug or turn OFF main power switch Leaving power on may cause unit failure or fire DO NOT place obstacles around air inlets or inside of air outlet Obstacles may cause appliance failure or a...

Page 6: ...curely and correctly installed according to the installation instructions in this manual Save this manual for possible future use in removing or installing this unit When handling the air conditioner...

Page 7: ...allation is not covered under the Warranty You MUST use only supplied parts and use proper installation procedures as described in these instructions when installing this air conditioner CAUTION DO NO...

Page 8: ...r the air conditioner CAUTION When the installation is complete replacement unit MUST have a rearward slope as shown STEP 2 REMOVE OLD AIR CONDITIONER Remove old air conditioner from wall sleeve and p...

Page 9: ...t s increased performance characteristics result from having two rear air intakes It is very important that these installation instructions are followed to ensure that your unit can operate at maximum...

Page 10: ...sleeve Attach the other 1 x x 14 long seal 4 from the right side of the sleeve 5 Center unit and gently slide unit into sleeve 6 Before sliding all of the way back remove second screw from front on l...

Page 11: ...n the center at the top of the sleeve Remove the backing paper and press into position 6 Attach 2 1 x x 14 long seals to the left and right sides of the sleeve 7 Cut 2 1 x x 25 long seal to 14 long an...

Page 12: ...x x 25 long seal in the center at the top of the sleeve Remove the backing paper and press into position 6 Attach 2 1 x x 14 long seals to the left and right sides of the sleeve 7 Cut 2 1 x x 25 long...

Page 13: ...eals to the left and right sides of the sleeve 6 Cut 2 1 x x 25 long seal to 14 long and attach to the vertical sections of the rear grille as shown 7 Center unit and gently slide unit into sleeve 8 B...

Page 14: ...the left and right sides of the sleeve 6 Cut 2 1 x x 25 long seal to 14 long and attach it to the vertical sections of the rear grille as shown 7 Center unit and gently slide unit into sleeve 8 Before...

Page 15: ...sides of the sleeve 6 Cut 2 1 x x 25 long seal to 14 long and attach it to the vertical sections of the rear grille as shown 7 Center unit and gently slide unit into sleeve 8 Before sliding all of th...

Page 16: ...olid vertical portion of the rear grille 10 Attach 2 4 x 3 x 1 foam blocks with the slot overlapping the seal above 11 Install the divider into the slots of the foam blocks You may need to trim the le...

Page 17: ...support blocks one on each side wall Place in center of side wall with the tapered end facing the opening 6 Gently slide unit into sleeve 7 Before sliding all the way back remove second screw from fr...

Page 18: ...14 long seal over the solid vertical portion of the rear grille 9 Attach 2 4 x 3 x 1 foam blocks with the slot overlapping the seal above 10 Install the divider into the slots of the foam blocks You...

Page 19: ...that a The double set of screw holes are at the bottom b The fins of the grille are pointed away from the unit 3 Align the top of the grille with the top of the unit and ensure that the overhang on ea...

Page 20: ...e wall sleeve and the unit A flat bladed screwdriver or putty knife is recommended 2 Assemble the trim frame by inserting top and bottom pieces into side pieces and snapping into place 3 Pull cord thr...

Page 21: ...remote control NOTE References to Heating HEAT in this manual are applicable only to units that have a built in electric heater for supplemental heating HEAT is not applicable to cooling only models...

Page 22: ...a mode is selected in a sequence that goes from AUTO COOL DRY HEAT units with heating function only and FAN The indicator light will be illuminated and remain on once the mode is selected The unit wil...

Page 23: ...the 4 way directional louvers to direct the air flow up or down and left or right throughout the room as needed Pivot horizontal louvers until the desired up down direction is obtained Move the center...

Page 24: ...ir filters CABINET CLEANING Be sure to unplug the air conditioner to prevent shock or fire hazard The cabinet and front may be dusted with an oil free cloth or with a cloth dampened in a solution of w...

Page 25: ...oil set to FAN only mode Then set temperature to a higher setting AIR CONDITIONER CYCLING ON AND OFF TOO FREQUENTLY OR NOT ENOUGH Be sure unit is not too large or too small for the area of the room Re...

Page 26: ...23...

Page 27: ...The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details...

Page 28: ...fect Aire LLC 5401 Dansher Rd Countryside IL 60525 844 4PA AIRE 844 472 2473 www perfectaire us Specification and performance data is subject to change without notice Printed in China PA User_3PATWH_3...