background image

 

 

 

1

3  

Max.

3/16  

Hole

3. If not existing, drill a 

1

/

8

” clearance hole for grounding screw through left side of

    sleeve, in a clear area about 3 inches maximum (to suit) back from front edge of 

    sleeve (as shown on right) using grounding screw and toothed washer. Pull loose 

    end of ground wire out front of sleeve, and temporarily bend it down and around 

    lower edge of sleeve. The ground wire will be attached to frame of air

    conditioner later once it is installed.

4. Prepare the wall sleeve for installation of the new unit per the following brand instructions:

 Brand

#1  Emerson   

15” deep

#2  Fedders    

19 

3

/

4

” deep

#3  Fedders or Friedrich 

16 

3

/

4

” deep

#4  General Electric/Hotpoint 

16 

7

/

8

” deep

#5  Sears or Carrier (51S Series)  18 

5

/

8

” deep

#6  Whirlpool 

17 

1

/

8

” deep

#7  Whirlpool 

23” deep

#8  Perfect Aire, Frigidaire 

16” & 17

1

/

2

” deep

 

White-Westinghouse,   

 

Carrier (52F Series)

#9  White-Westinghouse,   

22” deep

 

Frigidaire 

5. Install new unit into wall sleeve.
6. To attach ground wire to the new unit, remove the screw from the left side front.
7. Assemble and install the Trim Frame (see instructions).

IMPORTANT

• The unit’s increased performance characteristics result from having two rear air intakes.
• It is very important that these installation instructions are followed to ensure that your unit can operate at

  maximum efficiency.
• If this is an existing sleeve, and there is an existing rear grille, it needs to be replaced by one that has been 

  shipped with the unit in the accessory kit.

For increased efficiency, utilize the provided louvered rear panel.

Installation of new grille provided with unit:

1. Remove the existing grille.

2. Place the grille included with the new air conditioner

    towards the rear of the sleeve.

3. Mark the hole positions.

4. Drill through the sleeve’s flanges with a 1/8” drill bit.

5. Attach the new grille with self-threading screws and 

    washers (not included).

6. It is VERY IMPORTANT that the grille is placed exactly 

    as shown in the picture on the right.

7. Most decorative exterior grilles may be left in place as

    long as the proper interior air direction grille is installed.

INSTALLATION INSTRUCTIONS (CONTINUED)

11

Summary of Contents for 2PATWH12000

Page 1: ......

Page 2: ...ry The air conditioner is not intended for use by young children without supervision Young children should be supervised to ensure that they do not play with the air conditioner Disabled persons may r...

Page 3: ...nd burns Doing so may cause electric shock or fire due to heat generation Doing so may cause electric shock Doing so may cause failure of machine or electric shock Doing so may cause fire and electric...

Page 4: ...ime turn OFF main power switch If water enters the unit turn the unit off at the power outlet and switch off the circuit breaker Isolate supply by taking the power plug out and contact a qualified ser...

Page 5: ...zed repairman Operation of Current Device 1 Plug in the air conditioner 2 The power supply cord will have TWO buttons on the plug head Press the TEST button The RESET button will click as it pops out...

Page 6: ...earance of the control panel on the air conditioner purchased may be slightly different NORMAL SOUNDS AIR CONDITIONER FEATURES Before you begin thoroughly familiarize yourself with the control panel a...

Page 7: ...fan speed mode is shifted On Dry mode the fan speed is controlled at low automatically For some models with heating capabilities the fan speed cannot be adjusted under Heat mode NOTE The unit will aut...

Page 8: ...y and Auto only Auto Cooling and Auto Fan modes NOTE MODE button To operate on Auto feature To operate on Fan only not available on all models Use this function only when cooling is not desired such a...

Page 9: ...Auto Stop program is initiated Turning the unit on or off at any time or adjusting the timer setting to 0 0 will cancel the Auto Start Stop function This feature is a reminder to clean the Air Filter...

Page 10: ...ntal louvers until the desired up down direction is obtained Move the center handles from side to side until the desired left right direction is obtained Air Direction 4 way Read these instructions co...

Page 11: ...7 16 3 4 16 3 4 or 19 3 4 Sears Kenmore Carrier 51S Series 25 3 4 16 7 8 18 5 8 Fedders Emerson 26 3 4 15 3 4 15 Friedrich 27 16 3 4 16 3 4 Brand Width Height Depth Note Note Please verify dimensions...

Page 12: ...new unit remove the screw from the left side front 7 Assemble and install the Trim Frame see instructions IMPORTANT The unit s increased performance characteristics result from having two rear air in...

Page 13: ...ch 2 4 x 3 x1 centering support blocks one on each side wall Place in center of side wall with the tapered end facing the opening 6 Gently slide unit into sleeve 7 Before sliding all the way back remo...

Page 14: ...t 5 Attach 1 1 x 3 8 x 25 long seal in the center at the top of the sleeve Remove the backing paper and press into position 6 Attach 2 1 x 3 8 x 14 long seals to the left and right sides of the sleeve...

Page 15: ...at the top of the sleeve Remove backing paper and press into position 6 Attach 2 1 x 3 8 x 14 seals to the left and right sides of the sleeve 7 Cut 2 1 x 3 8 x 25 long seals to 14 long and attach to...

Page 16: ...of the sleeve 6 Cut 2 1 x 3 8 x 25 long seals to 14 long and attach to the vertical sections of the rear grille as shown 7 Center unit and gently slide unit into sleeve 8 Before sliding all of the wa...

Page 17: ...ition 5 Attach 2 1 x 3 8 x 14 seals to the left and right sides of the sleeve 6 Cut 2 1 x 3 8 x 25 long seals to 14 long and attach to the vertical sections of the rear grille as shown 7 Center unit a...

Page 18: ...3 8 x 14 seals to the left and right sides of the sleeve 6 Cut 2 1 x 3 8 x 25 long seals to 14 long and attach to the vertical sections of the rear grille as shown 7 Center unit and gently slide unit...

Page 19: ...ension into the room 9 Attach 1 x x 14 long seal over the solid vertical portion of the rear grille 10 Attach 2 4 x 3 x 1 foam blocks with the slot overlapping the seal above 11 Install the divider in...

Page 20: ...h 1 1 x x 14 long seal vertically 4 5 from the left side of the sleeve Attach the other 1 x x 14 long seal from the right slide of the sleeve 5 Center unit and gently slide unit into sleeve 6 Before s...

Page 21: ...sion into the room 8 Attach 1 x x 14 long seal over the solid vertical portion of the rear grille 9 Attach 2 4 x 3 x 1 foam blocks with the slot overlapping the seal above 10 Install the divider into...

Page 22: ...of screw holes are at the bottom b The fins of the grille are pointed away from the unit 3 Align the top of the grille with the top of the unit and ensure that the overhang on each side is equal 4 If...

Page 23: ...he unit A flat bladed screwdriver or putty knife is recommended 3 Pull cord through trim frame then slide in unit until flush with wall 2 Assemble the trim frame by inserting top and bottom pieces int...

Page 24: ...e air filter Never attempt to operate the unit without the air filter Be sure to unplug the air conditioner to prevent shock or fire hazard The cabinet and front may be dusted with an oil free cloth o...

Page 25: ...an filter Refer to Care and Cleaning section To defrost set to Fan Only mode Thermostat is set too cold for night time cooling To defrost the coil set to Fan Only mode Then set temperature to a higher...

Page 26: ...for Home Comfort Distributed by Perfect Aire LLC 5151 Belt Line Rd Suite 878 Dallas TX 75254 Specification and performance data is subject to change without notice Printed in PRC 877 365 6274 www per...

Reviews: