background image

Dehumidifier

OWNER’S MANUAL & INSTALLATION MANUAL

1020_M516

Perfect Aire, LLC

5401 Dansher Road

Countryside, IL 60625

Model 1PDP60

Summary of Contents for 1PDP60

Page 1: ...Dehumidifier OWNER S MANUAL INSTALLATION MANUAL 6 Model 1PDP60...

Page 2: ...d Case Cleaning the Bucket Cleaning the Air Filter When Not in Use Longer Time Periods Troubleshooting Tips 3 12 12 13 14 14 15 17 18 21 21 21 21 22 IMPORTANT NOTE Read this manual carefully before in...

Page 3: ...aust openings with cloths or towels Care should be taken when using the unit in a room with the following persons infants children elderly people and people sensitive to humidity Do not use in areas w...

Page 4: ...appliance in a location that may be exposed to combustible gas If combustible gas accumulates around the unit it may cause fire If the appliance is knocked over during use turn off the unit and unplug...

Page 5: ...cable to a unit using R290 Refrigerant CONTINUED Ensure the unit is properly grounded To minimize shock and fire hazards proper grounding is important The power cord is equipped with a three pronged g...

Page 6: ...ircuit should hold a current valid certificate from an industry accredited assessment authority which authorizes their competence to handle refrigerants safely in accordance with an industry recognize...

Page 7: ...resence of refrigerant The area should be checked with an appropriate refrigerant detector prior to and during work to ensure the technician is aware of potentially flammable materials Ensure that the...

Page 8: ...be corrected immediately but it is necessary to continue operation an adequate temporary solution should be used This should be reported to the owner of the equipment so all parties are advised Initi...

Page 9: ...the use of detergents containing chlorine should be avoided as the chlorine may react with the refrigerant and corrode the copper pipework If a leak is suspected all naked flames should be removed ex...

Page 10: ...with the equipment and it s operation b Isolate the system electrically c Before attempting the procedure ensure that i Mechanical handling equipment is available if required for handling refrigerant...

Page 11: ...erants In addition a set of calibrated weighing scales should be available and in good working order Hoses should be complete with leak free disconnect couplings and in good condition Before using the...

Page 12: ...th sides Control panel Water level window Water bucket Air Filter Continuous drain hose outlet Power cord buckle placed in the water bucket used only when storing the unit Air outlet grille Pump drain...

Page 13: ...ooth level floor strong enough to support the unit with a full bucket of water Allow at least 8 of air space on all sides of the unit for good air circulation at least 16 of air space on air outlet Pl...

Page 14: ...socket outlet which is also being used for other electrical appliances Select a suitable location making sure you have easy access to an electrical outlet Plug the unit into an electrical socket outl...

Page 15: ...fan speed Set the fan control to High for maximum moisture removal When the humidity has been reduced and quiet operation is preferred set the fan control to Normal Press to turn the dehumidifier on a...

Page 16: ...he unit with pump feature Eb Bucket is removed or not in right position Replace the bucket in the right position Only available for the unit with pump feature Press to activate the comfort dehumidifyi...

Page 17: ...power resumes When the unit is on first press the Timer button the Timer Off indicator light illuminates It indicates the Auto Stop program is initiated Press it again the Timer On indicator light il...

Page 18: ...hrow away the water and replace the bucket The bucket must be in right place and securely installed for the dehumidifier to operate The machine will re start when the bucket is restored in its correct...

Page 19: ...oward the drain making sure that there are no kinks that will stop the water flowing Make sure the water hose is lower than the drain hose outlet of the unit Select the desired humidity setting and fa...

Page 20: ...make sure the end of the hose is level or down to let the water flow smoothly Select the desired humidity setting and fan speed on the unit for pump draining to start Please turn off the unit and dis...

Page 21: ...tic bag Store the unit upright in a dry well ventilated place Every few weeks clean the bucket to prevent growth of mold mildew and bacteria Partially fill the bucket with clean water and add a little...

Page 22: ...ther openings are securely closed Room temperature is too low below 41 F There is a kerosene heater or something giving off water vapor in the room The unit makes a loud noise when operating The air f...

Page 23: ...s are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details Any updates to the manual will be uploaded to the service website please...

Page 24: ...844 4PA AIRE 844 472 2473 www perfectaire us 1020_M516 Perfect Aire LLC 5401 Dansher Road Countryside IL 60625 Printed in China...

Reviews: