WMD-06 Motorized electromechanical swing gate  

4.2  Optional equipment (upon request) 

In addition to the standard delivery set the following equipment can be supplied on request: 

Power supply unit  .........................................................................................................................1 
WRC kit

1

 .......................................................................................................................................1 

DESCRIPTION 

5.1  Main features 

  The swing gate can operate both as a standalone unit and as a part of the ACS. Two control 

modes are available: pulse control mode and potential control mode. 

  The swing gate can be supplied with two types of swing panel: 650 mm or 900 mm. Overall 

dimensions of the gate are shown in Fig. 1

  External components of the swing gate (except for swing panel) are made of polished stainless 

steel. The swing panel is made of 10 mm thick tempered glass. 

  The swing gate is a normally open unit i.e. in case of power failure the swing panel can rotate 

±90º. 

  Safe operating voltage – max. 28 V. 

  Low power consumption – max. 105 W. 

5.2  Design 

Design of the swing gate is shown in Fig. 2. The numbers of the items in brackets are given 
according to Fig. 2, unless stated otherwise. 
The gate consists of the fixed base (1), rotary support (7) that holds glass panel (4), housing (2) 
and cover (3). The metal (5) and plastic rings (12) provide support of housing (2) and its rotation 
around fixed base (1). Decorative plate (15) is fixed with a screw (16). 
The gate post is installed on anchors stud-bolts (9) and fixed with nuts (10) and washers (11)  
The gate post contains units providing its operation: rotary electric drive with rotation sensor, 
electromagnetic stopper unit, bearing units, drive control board (6). 
RC panel is included into delivery set (17). 
The gate is operated with +24 V DC voltages via cable (13). 
The control board is installed inside the gate post. The control board overview is shown in Fig. 3
The control board contains: 

 

XT1

 and 

XT2

 – terminal blocks are designed for power supply, input-output of control signals 

and indication. Marking and description of 

XT1

 and 

XT2

 terminal block contacts of the control 

board are given in Table 1. 

 

Size

 – connector is designed for selection of swing panel type installed on the gate. If the 

AGG-900

 panel is used, the jumper shall be removed, if the 

AGG-650

 panel is used – the 

jumper shall be installed. The jumper is removed by default. 

 

Imp / Pot

 – connector is designed for selecting gate control mode. If the jumper is installed, 

the gate operates in the pulse mode, if the jumper is not installed, the gate operates in the 
potential mode. The jumper is installed by default. 

 

FireAlarmDir

 – connector is designed for selecting gate opening direction when the 

Fire 

Alarm

 emergency unlocking signal is applied. If the jumper is installed, the swing panel opens 

in direction A (see Figure 5), if the jumper is not installed, the swing panel opens in direction B. 
The jumper is installed by default. 

 

LED

 – connector is designed for turn-off of LED indicators located on the control board. If the 

jumper is installed, indication is on. If the jumper is not installed, indication is off. The jumper is 
installed by default. 

                                                 

1 WRC kit consists of a receiver connected to the gate control board and two transmitters (tags) with 
operating range up to 40 m. 

 

5

Summary of Contents for WMD-06

Page 1: ...ASSEMBLY AND OPERATION MANUAL WMD 06 Motorized Electromechanical Swing Gate ...

Page 2: ...WMD 06 Motorized electromechanical swing gate Assembly and Operation Manual ...

Page 3: ...QUIREMENTS 12 7 1 Installation safety 12 7 2 Operation safety 12 8 ASSEMBLY AND INSTALLATION 13 8 1 General recommendations 13 8 2 Tools and equipment required for installation 13 8 3 Appropriate cable length 13 8 4 Installation procedure 13 9 OPERATION 16 9 1 Power up 16 9 2 Pulse control mode 17 9 3 Potential control mode 17 9 4 Emergency situations 18 9 5 Troubleshooting 18 10 TRANSPORTATION AN...

Page 4: ...sed as a separate device It is recommended to define the number of swing gates necessary to secure fast and convenient passage in accordance with throughput rate see Section 3 For example it is recommended to install one turnstile per 500 people on the basis of maximum working load of 12 persons min 2 OPERATING CONDITIONS The swing gate with regard to resistance to environmental exposure complies ...

Page 5: ...0 mm passageway width is chosen by the customer RC panel with cable 1 SW1 5 Allen wrench 1 Gate mounting kit PFG IH 10 SORMAT Finland anchor bolt with washer and M10 nut 3 Panel installation kit M10 35 bolt 4 M10 nut 4 Spring washer 4 Expanded washer 8 Plastic bushing 4 Operational documentation Certificate 1 Assembly and operation manual 1 Template for gate installation 1 Package Box 1 gate post ...

Page 6: ...electromagnetic stopper unit bearing units drive control board 6 RC panel is included into delivery set 17 The gate is operated with 24 V DC voltages via cable 13 The control board is installed inside the gate post The control board overview is shown in Fig 3 The control board contains XT1 and XT2 terminal blocks are designed for power supply input output of control signals and indication Marking ...

Page 7: ...base 2 housing 3 cover 4 glass panel 5 metal ring 6 control board 7 rotary support 8 M3 screw 3 pcs 9 anchor stud bolt 10 M10 nut 11 washer 12 plastic ring 13 power cable 14 control cable from RC panel WRC device ACS controller 15 decorative plate 16 screw M4 17 RC panel 6 ...

Page 8: ...trol board Terminal block No Item Designation 1 24 V 2 GND External power supply connection 3 NO 4 C 5 NC Light A relay contacts remote indicator connection for direction А 6 NO 7 C 8 NC Light B relay contacts remote indicator connection for direction В 9 12 V Power supply positive terminal of RC panel 10 GND Power supply negative terminal 11 Common Common contact for PASS А PASS В signals 12 Pass...

Page 9: ...C panel features three control buttons to set swing gate passage modes The buttons LED indicators are located above The STOP button in the middle serves for setting the Always locked operating mode the RIGHT and LEFT buttons for allowing passage in the chosen direction The RC panel features a built in piezoelectric buzzer for audio signals generation The standard orientation of the RC panel in rel...

Page 10: ...tput signals from rotation sensor Upon received data the microcontroller generates commands for the gate control mechanism and also signals for connected external indication devices indication on the RC panel Led A Led Stop and Led B signals on the performed rotation of the swing panel on outputs Pass А and Pass В 5 4 1 Inputs for control devices connection The swing gate can be operated with RC p...

Page 11: ...be used as a control element If the Fire Alarm input is not used it is necessary to install a jumper between Fire Alarm and GND contacts on the XT2 terminal block The jumper is installed by default The gate can operate in two control modes pulse and potential Control mode is set by installing or removing the jumper on Imp Pot connector If the jumper is installed the gate operates in the pulse cont...

Page 12: ...l specifications maximum switching voltage 42 V DC maximum switching current 0 25 А closed contact resistance max 0 15 Ohm 5 4 3 Outputs for external indication connection Light A and Light B outputs are used for external indication connection and are basically relay changeover contacts see Fig 9 Each output has full contact set on XT1 terminal block normally open NO normally closed NC and common ...

Page 13: ...eing damaged during transportation and storage The box 1 contains gate post and RC panel the box 2 contains a swing panel Boxes have the marking of the packed product and additional marking in accordance with design documents and delivery set Dimensions L W H box 1 121 37 22 cm box 2 for AGG 650 glass panel 96 12 90 cm box 2 for AGG 900 glass panel 121 12 90 cm Gross weight box 1 max 36 kg box 2 f...

Page 14: ... Appropriate cable length Maximum acceptable length of RC panel ACS controller cable 30 m Maximum acceptable length of power supply cable depends on its cross section and shall be as following for 1 5 mm2 cross section AWG 15 max 10 m for 2 5 mm2 cross section AWG 13 max 20 m 8 4 Installation procedure Attention The manufacturer shall not be liable for any damage caused in the result of improper i...

Page 15: ...e the metal ring 5 Put a washer 11 on each anchor and fix the gate post with three M10 nuts 10 9 Connect power cable and control cable to XT1 and XT2 terminal blocks of the control board 6 Put cables as shown in Fig 3 10 If needed connect Fire Alarm emergency unlocking device If the device is not connected a wire jumper shall be installed on Fire Alarm and GND contacts on XT2 terminal block 11 If ...

Page 16: ... of the swing gate 24V DC 4А А3 Power supply unit of remote indicators A4 A5 Remote indicators 2 pcs A6 1 ACS controller input A6 2 ACS controller output A7 Device sending Fire Alarm FA emergency unlocking signal A8 RC panel PERCo H6 4 A9 WRC device 1 Wire jumper Installed when the Fire Alarm device А7 is not connected Installed on default Not included in standard delivery set 15 ...

Page 17: ...y cause mechanical damage or corrosion of the surfaces 9 1 Power up Attention Make sure that there are no obstacles in the rotation zone and passageway of the gate before starting the power up Perform the following actions in order 1 Connect the power cable to the electric socket with voltage and frequency set in the certificate of the power supply unit 2 Turn the power supply unit on 3 The swing ...

Page 18: ...c in the Single passage in chosen direction mode Timing starts after the swing panel rotates 85º After that the swing panel moves to Closed position and locks the swing gate switches to the Always locked mode Single passage in chosen direction mode can be changed to Free passage mode in the same direction or to Always locked mode Always free mode can be changed to Always locked mode only 9 3 Poten...

Page 19: ...t the PERCo Technical Support Department Table 6 Troubleshooting Fault Possible cause Remedy When powered up RC panel indication does not work No supply voltage on control board De energize power supply unit Remove the cover and housing of the gate Check the power cable and its connection to the XT1 terminal block The gate cannot operate in one of the directions RC panel indication is on Control s...

Page 20: ...at the contact Unlock A while there is a low level at the contact Stop and a high level at the contact Unlock B or active front is at the contact Stop while there is a low level at the contact Unlock A and a high level at the contact Unlock B At this command the passage direction А opens until the command Always locked is received the status of the passage direction В does not change at that Free ...

Page 21: ...PERCo Polytechnicheskaya str 4 block 2 194021 Saint Petersburg Russia Tel 7 812 247 04 64 E mail export perco com support perco com www perco com ...

Page 22: ...www perco com ...

Reviews: