FP-11Q.1

 

Front panel with barcode scanner for ST-11 Speed gate 

Remove the panel and drill holes in the mounting surface for anchors to secure the panel. Insert 
anchors into holes. 

6.  Connect scanner and ACS controller. 

7.  Using  a  cable  (3),  connect  the  front  indication  module  (2)  to  the  indication  plate  in  the 

ST-11

 

section. The procedure for connecting cables to the indication plate is shown in Fig. 2: 

  so that the white arrow on the front indication module lights up - the cable from the end block 

must be connected to the ARROW connector on the indication plate; 

  so that the red cross is lit on the front indication module 

– the cable from the end block must 

be connected to the CROSS connector on the indication plate. 

8.  Final install 

FP-11Q.1

 front panel back on 

ST-11 

speed gate and fix it with anchor bolts on the 

mounting surface. Close the front panel cover. 

9.  Reinstall  the 

ST-11

  top  cover,  don't  forget  to  connect  the  indicator  cable  of  the  artificial  stone 

cover to the LIGHT connector of the indication plate (see Fig. 2). 

 

Figure 2. FP-11Q.1 front panel 

– 

MERTECH N160 P2D

 barcode scanner; 2 

– front indication module;  

– front indication module cable; 4 – front panel cover; 5 – front panel cover lock;  

– bracket to fix an ACS controller; 7 – screws to fix the bracket  

5  PERCO WARRANTY  

PERCo  (the  Manufacturer)  warrants  that  the 

FP-11Q.1  Front  panel

  (the  Product)  complies  with 

applicable statutory safety requirements, electromagnetic compatibility provided that the instructions 
on storage, installation and operation, given in the Assembly & Operation Manual, are observed.  

The warranty period is 

5 (five) years 

commencing from the date of sale. 

Should there be no date of sale on the warranty card, the warranty period shall commence from the 
date of manufacture specified in the Certificate and on the Product label. 