The  Manufacturer  reserves  the  right  not  to  accept  the  Product for  repair  from  the  Customer  who 
failed to submit the Technical Support Form. 

The Manufacturer’s warranty obligations don’t cover attendance by the experts  

of a Customer and maintenance of any Product on site 

If  in  the  course  of  the  examination  taken  by  the  Manufacturer  of  the  Product  or  its 
parts/components believed to be faulty, no faults have been detected, the Customer is responsible 
for compensation of the Manufacturer’s expenses related to the examination. 

Apart  from  the  warranties  mentioned  above  the  Manufacturer  does  not  provide  any  other 
warranties with regard to compatibility of a Product purchased with software or products produced 
by  other  manufacturers  as  well  as  any  warranties  that  this  Product  will  fit  for  the  purposes  not 
stipulat

ed in the Product’s in-line documentation. 

The  warranty  does  not  provide  for  any  claims  with  regard  to  the  technical  specifications  of  the 
Product  in case they  are  in  compliance  with  those  stated  by  the  Manufacturer.  The  Manufacturer 
does  not  guarantee  tha

t  the  Product  purchased  will  meet  Customer’s  requirements  and 

expectations.  

PLEASE NOTE THAT PERCo PRODUCES TECHNICALLY  

SOPHISTICATED PRODUCTS THAT, IF NOT FAULTY,  

CANNOT BE RETURNED BACK IF BY SOME REASON 

THE CUSTOMER DEEMS THEM UNSATISFACTORY 

 

 

The PERCo 

FP-01C Front panel

 is in conformity with the essential requirements of 

the EU’s Machinery, Low-Voltage and EMC Directives and carries the CE marking 

accordingly. 

 

Summary of Contents for FP-01C

Page 1: ...er can be used as a part of PERCo access control systems in this case data is transferred via RS 485 interface from a built in reader of the card capture reader to the PERCo ACS controller Card captur...

Page 2: ...se without prior notice 2 TECHNICAL SPECIFICATIONS DC operating voltage 21 6 28 V DC Current consumption min 1 81 A Power consumption max 56 W Card container capacity 150 3002 Mean time before failure...

Page 3: ...ght remains constant 3 If the presented card is a temporary visitor s card and should be withdrawn then the ACS controller sends the signal to the card capture reader control board input Capture card...

Page 4: ...contact COM 42 V the maximum switching current 200 V Figure 2 Card capture reader control board Card capture reader control board layout is shown in the Fig 2 There are terminal blocks on the board T1...

Page 5: ...Fig 3 Figure 3 FP 01C Front panel 1 card slot 2 front end indication module 3 container lock 4 container 5 panel fixing hooks 6 built in reader1 7 connection cable of module with indicators1 8 cable f...

Page 6: ...hooks 5 4 Install back the speed gate glass cover 5 2 Connection layouts of a built in card capture reader Figure 4 Diagram for connecting the card capture reader to the PERCo ACS controllers via RS...

Page 7: ...FP 01C Front panel for ST 01 Speed gate 7 Figure 5 Diagram for connecting the card capture reader to the ACS controller via Wiegang interface list of components mentioned in the Table 1...

Page 8: ...t is not backlit Faulty connection or breakdown of power supply cable 9 Faulty power supply unit Replace the cable of the card capture reader 9 Replace the power supply unit The LED indicators are on...

Page 9: ...Normal state parameter 8 Switch to Additional inputs tab 9 If the card capture reader acts as an external verification device for the controller Card captured signal is sent to a separate input of th...

Page 10: ...rop down menu set Standard value for Type parameter set Disconnected value for the Normal condition of the contact parameter configure controller response to the activation of the input No 5 by using...

Page 11: ...ler in parallel with the RC In this case it is also necessary to check In Control mode box on the left side of the Remote control permission window Check boxes of the Verify VISITORS IDs from the exte...

Page 12: ...lick Save and close button The Device properties window will be closed the settings are saved 5 4 2 CT L14 CT13 configuration in Web interface for working with the card capture reader 1 In Configurati...

Page 13: ...ing parameter values for input that is physically connected to the Card captured output of the card capture reader Function External verification device confirmation input Operating device 1 number of...

Page 14: ...capture reader It is necessary to set the type of response on the activation of this input for example activate alarm output 5 Temporary cards for visitors can be issued in Access Users section of the...

Page 15: ...ication parameter within the External device verification in ACM Control group of parameters set Yes value for the Visitor pass verification parameter and also set the required values for Visitor veri...

Page 16: ...rolled by the card capture reader Receiver type Activate output Receiver number 3 number of the output that is physically connected to the Capture card input of the card capture reader Response charac...

Page 17: ...rds section of the Web interface First include them into the main list of cards in the Input subsection then in the List subsection select the proximity card that should be issued for a visitor and in...

Page 18: ...proper testing operation installation maintenance modification alteration or adjustment damages due to force majeure circumstances natural disasters vandalism etc or defects as a result of external ci...

Page 19: ...ies with regard to compatibility of a Product purchased with software or products produced by other manufacturers as well as any warranties that this Product will fit for the purposes not stipulated i...

Page 20: ...e of sale ____________________ 20___ ____________________________________ signature seal Cutting line Warranty Repair Coupon FP 01C Front panel with a built in card capture reader for ST 01 Serial num...

Page 21: ......

Reviews: