WARNING AND ADVICES 

 
Please read the warning notices very carefully because they provide important information regarding safety in 
installation, maintenance and use of the pump. 

 

Keep this manual in a safe place, so that it will always be available for further consultation. 

 

The device complies with EMC: 2004/108/EEC “electromagnetic compatibility” and LVD: 2006/95/EC “ low 
voltage ” as also the subsequent modifications. 

N.B.

 : the pump has been constructed in accordance with best practice. Both its life and its electrical and mechanical 

reliability will be enhanced if it is correctly used and subjected to regular maintenance. 
 

1.1

 

 

Guarantee and Warning

 

 

1.1.1  General equipment 

The material is guaranteed 24 months parts and labour. The return address in our center is the following : 

PERAQUA Professional Water Products GmbH 

Handelsstraße 8 

4300 St. Valentin - Austria 

The shipping costs are charged of the customer. If the repair is  carried out as part of the warranty, return is 
supported by Peraqua. The wear parts excluded of the warranty are: pH or redox probe (except for the validation 
of the warranty extension), injection valve, foot filter and peristaltic hose. 
 

 

WARNING

 : any intervention or repair to the internal parts of the pump must be carried out by 

qualified and authorized personnel. The manufacturers decline all responsibility for the 

consequences of failure to respect this rule. 

 
 

1.1.2  Warranty extension for the sensor  

 

Applicable conditions

 : The user's purchase must be declared on the PERAQUA website (

www.peraqua.com

) within 

one month. The warranty runs for 12 months from the date of. The warranty consists of the direct replacement of 
the sensor identified as being faulty by our Technical Department, or its repair, after examination by our Technical 
Department, excluding any other compensations of whatever form. 
 

Exclusion conditions

 : This warranty does not cover damage caused by an accident, improper installation or use, a 

lack of reasonable care, attempted falsification or attempted repair performed by an unauthorised person. 
 

Return conditions

 :  

 

The probe's serial number must always be on its cable and readable as at the time of purchase. 

 

A photocopy of the purchase receipt must be sent together with the return package. 

 

The sensor must be sent in its original packaging with the extremity protected by its cap and filled with 
water. 

The transport costs to our company must be paid by the customer. However, for sensors under warranty, the return 
transport costs will be paid by PERAQUA. 
 

 

Summary of Contents for iQntrol DOS-ECO

Page 1: ...www peraqua com DOS ECO INSTRUCTIONS AND USER MANUAL...

Page 2: ...scription 9 3 RECOMMENDATIONS AND INSTALLATION 9 3 1 Recommandations 9 3 2 Hydraulic and electrical installation principle 10 3 3 Device Dimensions 11 3 4 Device installation 11 4 ADVANCED DEVICE SETT...

Page 3: ...Instructions and user manual DOS ECO NOT041ENV01_FP1 3 6 3 Installation of a long probe 120 mm 32 6 4 Peristaltic tube replacement 33 6 5 Wintering 33 7 AFTER SALE SERVICE 34 8 SPARE PARTS LIST 35...

Page 4: ...lve foot filter and peristaltic hose WARNING any intervention or repair to the internal parts of the pump must be carried out by qualified and authorized personnel The manufacturers decline all respon...

Page 5: ...efore be used for applications that were not allowed for in its design In case of doubt please contact our offices for further information about the characteristics of the pump and it proper use The m...

Page 6: ...diately be brought to a stop emptying and depressurizing the delivery hos while taking all due the safety precautions gloves goggles overalls etc 1 5 Toxic and or dangerous liquid dosage To avoid risk...

Page 7: ...ts configuration 2 1 Parts description The complete list of accessories delivered with the equipment is given below All the parts will be necessary for the correct operation of your unit A1 pH4 pH7 ca...

Page 8: ...f selections Long press Increases a numerical value quickly Short press Switch from one display to an other Exit current menu Long press Give access to the installation configuration with SET Increase...

Page 9: ...o a few weeks and oxidise the pump s s metallic parts In this case the warranty is voided The stabilizer rate must be less than 15 ppm in order not to disturb the reading of the redox The use of chlor...

Page 10: ...control of the swimming pool circulation pump E Pool water circulation pump F Pool G Pool filtration i Electrical cable for wire detection connected in electrical box D Warning Under no circumstances...

Page 11: ...Instructions and user manual DOS ECO NOT041ENV01_FP1 11 3 3 Device Dimensions Height 260 mm Width 220 mm Depth 130 mm 3 4 Device installation STEP 1 Mounting the housing 220 mm 260 mm...

Page 12: ...g tool F Positioning on a horizontal pipe 1 Remove the sensor s protective cap and keep it to re use it for the winter shutdown period 2 Leave the sensor submerged in tap water for at least 20 minutes...

Page 13: ...Instructions and user manual DOS ECO NOT041ENV01_FP1 13 Positioning on a vertical pipe...

Page 14: ...Instructions and user manual DOS ECO NOT041ENV01_FP1 14 STEP 4 Preparation of the probe holder Mount the O ring H under the support flange B Remove the cap and store 1 2...

Page 15: ...Instructions and user manual DOS ECO NOT041ENV01_FP1 15 STEP 5 Position the support flange by inserting the injection pipe in the direction of flow 1 2 Q 3...

Page 16: ...Instructions and user manual DOS ECO NOT041ENV01_FP1 16 STEP 6 Attachment to the pipe 50 pipe 63 pipe C L K K C L O...

Page 17: ...A2 in parallel with the coil of the filter pump relay The voltage to be applied to this cable is 230V This means that the unit will only be supplied with power when the filter pump is switched on 2 C...

Page 18: ...L Connecting the suction lances to the unit 2 protective covers for Jack sockets Remove the 2 protective covers from the sockets Jack Plug the Jack plug into the socket If you remove the suction lance...

Page 19: ...water CALIBRATING pH 4 4 25pH 90s 7 25 is an example of instantaneous measurement before calibration values are commonly between 6 5 and 7 5 6 9pH SET CAL 6 9pH 720mV 720mV SET CAL Tip PRESS THE ESC K...

Page 20: ...100 475mV press OK 720mV SET CAL Tip PRESS THE ESC KEY AT ANY TIME TO EXIT THE CALIBRATION PROCEDURE 6 9pH 720mV After pressing OK the unit continues operating normally 462mV is an example of instanta...

Page 21: ...Instructions and user manual DOS ECO NOT041ENV01_FP1 21 STEP 12 Installation of the probe pH J1 and Rx J2 2 3 1...

Page 22: ...refer to the following chapters to adjust the advanced settings as required Cut tube J to connect foot filter E to the left inlet of the pump and probe holder D to the right inlet of the pump Place fo...

Page 23: ...E VALUE WILL BE MEMORIZED Setting range of 6 5 to 7 6 pH 6 9pH SET CAL 6 9pH 720mV 720mV SET CAL Tip To adjust the chlorine setpoint press one more time the MENU ESC SETPOINT 700mV WHEN THE SET BUTTON...

Page 24: ...setpoint the longer the instrument activates the dosing The closer the measured value is to the desired value setpoint the shorter the dosing time Pool size Pump Acti Time S 0 1 pH Pump Acti Time S mV...

Page 25: ...FLOW RATE pH pump flowrate information no setting OVERDOSING ALARM Refer to section Erreur Source du renvoi LANGUAGES FRAN AIS ENGLISH DEUTSCH NEDERLANDS PORTUGUES ESPAGNOL ITALIANO MEASURE OFFSET Fr...

Page 26: ...mp flowrate setting 1 5 by default adjustable from 0 1 to 99 9 l h OVERDOSING ALARM Refer to section 4 4 4 LANGUAGES FRAN AIS ENGLISH DEUTSCH NEDERLANDS PORTUGUES ESPAGNOL ITALIANO PUMP ACTIVA TYPE PR...

Page 27: ...NY TIME TO EXIT MENU EXTERNAL INPUT ON by default OFF CONFIGURATION SYS TECHNICAL DETAIL NO TECHNICAL DETAIL YES NO Displays the offset and gain measurements for the after sales service LANGUAGES FRAN...

Page 28: ...d OVERDOSING ALARM 0 05 l 4h Adjusting the overdose alarm above the defined threshold the pump enters a state of alarm and requires that the CAL OK button be pressed to start again To disable the alar...

Page 29: ...to save power A short press of SET or CAL turns it on 5 SOLUTIONS TO PROBLEM 5 1 Incorrect measure and procedure for increasing the TAC If the displayed value on the device differs from the value obta...

Page 30: ...rresponding reservoir with fluid MEASURE TOO LOW pH mode measured pH 5 pH REDOX mode mesurement 100 mV Check pool water parameters TAC 100 mg L Check the status of the probes cable MEASURE TOO HIGH pH...

Page 31: ...ity of the more or less calcareous water the measurement will deteriorate A thin film of limescale will be deposited on the sensitive element of the probe together with other elements present in the p...

Page 32: ...Instructions and user manual DOS ECO NOT041ENV01_FP1 32 6 3 Installation of a long probe 120 mm J G P 1 2 3...

Page 33: ...one grease 6 5 Wintering 6 5 1 Pum wintering It is important to know that for the winter shutdown of your unit it is the peristaltic tube that needs protecting It is then recommended to pump clean wat...

Page 34: ...filled to 1 3 with AYACSOLSTK01 storage solution and the protective cap placed on the sensor s extremity This assembly must be stored away from freezing conditions at ambient temperature 7 AFTER SALE...

Page 35: ...10 RPM 230 240 Vac motor 3L h pump 7 6 9mm peristaltic tube 8 Roller holder kit transparent cover tube 6x9 9 pH probe Rx probe 10 EPDM 11 9 X 2 62 O rings per 10 units 11 2 in 1 probe holder 12 Probe...

Page 36: ...uctions and user manual DOS ECO NOT041ENV01_FP1 PERAQUA Handelsstra e 8 4300 St Valentin Austria Mail info peraqua com Web www peraqua com Instruction and user manuals are included with new products N...

Reviews: