4.1.4.4- Clock
The equipment has a time clock, which will be taken as the reference when
programming times of the auxiliary relays. If the equipment is switched OFF,
clock will keep on time.
4.1.4.5 Flow switch
The flow sensor detects whether or not there is water flow in the piping. If it
detects that there is no flow, the production will stop, and an alarm will sound
accompanied by a red warning LED. Once the flow has been reestablished, the
equipment will return to normal operation.
The "Flow Kit" (optional) is necessary to activate the flow sensor, which is
done by pressing Flow Switch = ON.
4.1.4.6- Cover
On placing the cover, the chlorinator automatically reduces production to 20%
,
C letter will appear to it, it means cover is activated.
This variation will be
reflected in the production %. It can be enabled of disabled by toggling Cover
= ON/OFF.It is considered a normally open contact
If chlorination is carried out with the cover in place, when it is
removed, the pool should not be used straightaway. It is
better to wait ½ hour for any vapours between the water and cover
to dissipate.