Commissioning
•
Version B:
The interface module is located at the beginning of the data line; one reading head is
located at the end of the data line. Both need the RS 485 terminator. The second reading
head is connected to the line connection between the interface module and the first
reading head through a short spur (length < 1 m). Use bus terminal BT111 to connect the
spur.
Figure 6.3: Connection of
two
reading heads, Version B
The wiring version used depends on which is best suited for the application. If
three
or
four
reading heads
are used on the same interface module, connect these using spurs as shown in
version B.
Reading head
Reading head
Interface or control
(PLC)
Spur line (max. 1 m)
Bus terminal