![Pepperl+Fuchs WCS DG310 Manual Download Page 19](http://html1.mh-extra.com/html/pepperl-fuchs/wcs-dg310/wcs-dg310_manual_1527703019.webp)
Appendix
2
0
1
7
-1
2
19
5.4
Data from WCS Reader
Meaning of A1 and A0
Function number for WCS reader F0=0 (send position value)
Function number for WCS reader F0=1 (send diagnosis result)
A1
A0
Reader address
0
0
Read head address 0
0
1
Read head address 1
1
0
Read head address 2
1
1
Read head address 3
DB
ERR
OUT
Description
Optical state
of WCS reader
0
0
0
Current position value binary coded in P00...P18
Good
0
0
1
WCS reader outside of the code rail, not a position
value
Good
P0...P18=0: WCS reader partly outside the code
rail
P0=1, P2 to P18=0: WCS reader completely
outside of the code rail
1
0
0
Current position value binary coded in P00...P18
Poor
1
0
1
No position value, WCS reader outside of the code
rail
Poor
X
1
X
No position value, error message from WCS
reader, error number binary coded in P00...P18
-
DB
ERR
OUT
Description
Optical state
of WCS reader
1
0
0
Diagnosis invalid, WCS reader not outside of the
code rail
-
1
0
1
Diagnosis result in P16...P18
P16...P18=0
Good
P16...P18>0
Poor
X
1
X
Error message from WCS reader, error message
binary coded in P00
P04
-