background image

VBA-4E4A-G20-ZEJ/M3L-P9

Troubleshooting

 2

0

2

1

-0

5

23

6

Troubleshooting

Fault information and remedy

Error

LED status indi-
cator

Possible cause

Remedy

No data commu-
nication with AS-
Interface master

PWR off

AS-Interface voltage is missing or is 
inverted

Check AS-Interface wiring

PWR flashes and
FAULT on

Module address is 0

Program module address

PWR on and 
FAULT on

AS-Interface master is not switched 
on (offline) or
There is duplicate addressing

Switch on the AS-Interface master 
or
Check the addresses of all modules 
on the AS-Interface segment

Motors do not 
start

AUX off

AUX external power supply is miss-
ing

Check AUX voltage and AUX flat 
cable

AUX red on

AUX external power supply is 
inverted

Correct the polarity of the AUX flat 
cable in the cable guide

AUX green on 
and
FUSE1 (motor 1) 
and/or FUSE2 
(motor 2) off

Motor fuse is faulty due to overload 
of the motor supply

Replace the motor control module 
(cannot be repaired) and remove 
the cause of the overload before 
starting the motor again

PWR and FAULT 
flash alternately

Peripheral fault "Overload speed 
signal SPEED": 
Motor, motor cable, or motor control 
module is faulty

Replace motor or motor control 
module

Sensors or 
inputs IN1 ... IN2 
not working

PWR and FAULT 
flash alternately

Periphery fault: overload on sensor 
supply

Check the sensors and eliminate 
the overload

Table 6.1

Summary of Contents for VBA-4E4A-G20-ZEJ/M3L-P9

Page 1: ...VBA 4E4A G20 ZEJ M3L P9 AS Interface motor control module Manual...

Page 2: ...sion as well as the supplementary clause Expanded reservation of proprietorship Worldwide Pepperl Fuchs Group Lilienthalstr 200 68307 Mannheim Germany Phone 49 621 776 0 E mail info de pepperl fuchs c...

Page 3: ...UL Information 7 3 Product Description 8 3 1 Use and application 8 3 2 Housing 8 3 3 Displays and operating elements 9 3 4 Interfaces and connections 11 3 5 Accessories 12 4 Installation 13 4 1 Storag...

Page 4: ...icable EU type examination certificate EU declaration of conformity Attestation of conformity Certificates Control drawings Instruction manual Other documents 1 2 Target Group Personnel Responsibility...

Page 5: ...rs or compatible types The motor control module has two inputs for connecting three wire sensors Read through these instructions thoroughly Familiarize yourself with the device before install ing moun...

Page 6: ...using the device Secure the device against unintended operation To have the device repaired return it to your local Pepperl Fuchs representative or your sales center 1 6 Declaration of Conformity Thi...

Page 7: ...or indoor use only This device may be operated in altitudes up to 2000 m The ambient temperature range is from 25 C to 70 C The device must be installed in accordance with applicable national laws and...

Page 8: ...power supply may be loaded in total with 100 mA For each motor a maximum current load of 5 A is permitted briefly 2 s Figure 3 1 VBA 4E4A G20 ZEJ M3L P9 motor control module Essential function and app...

Page 9: ...Peripheral fault Display of the AS Interface operating states The AUX LED shows the status of the AUX external auxiliary voltage supply 100 120 122 135 5 8 16 6 15 27 5 25 8 54 LED PWR Green LED FAULT...

Page 10: ...X external auxiliary voltage is inverted Off AUX external auxiliary voltage is missing LED FUSE1 LED FUSE2 Green Status On Power supply for motor is OK Off Power supply for motor is missing Fuse is fa...

Page 11: ...sensors and motors are connected to the motor control module via cables with round M8 connectors Sensors socket 4 pin Motors socket 5 pin The cable length is 1 m LED DIR Yellow Status On Direction of...

Page 12: ...pin socket screw locking coding A Suitable counterpart connector M8 4 pin plug screw locking coding A IN1 IN2 1 IN sensor supply 2 Not used 3 IN sensor supply 4 IN input Motor Motor in accordance with...

Page 13: ...ut the needs for tools The profiled flat cables have a narrow upper side with a visibly offset profile edge and a wide under side profile edge not visible The cable guide allows the flat cables to be...

Page 14: ...this push the locking bracket 1 slightly to one side 2 Insert the black AUX flat cable with the profile edge 3 to the motor control module into the lower guide see the module tag Black AUX 3 Insert th...

Page 15: ...at cable The profile edge 2 does not point to the motor control module the flat cable is therefore inserted with reverse polarity The flat cable is located on the reverse polarity protection 1 with a...

Page 16: ...Connecting motors and sensors Figure 4 4 Connection wiring diagram for motors and sensors n c PWR AUX AUX AS Interface AS Interface FAULT AUX 1 4 3 2 IN 1 2 4 5 3 FUSE IN1 IN2 IN IN IN MOT1 MOT2 MOT...

Page 17: ...e sets the output data DO0 DO3 to logical 0 Starting Stopping motors DO0 DO1 You can start or stop the motors separately via bits DO0 and DO1 To start motors you must set the corresponding data bit to...

Page 18: ...This always applies to both motors simultaneously To do this you must parameterize 1 of 4 predefined speed values The speed values correspond to analog voltage values If the master does not change the...

Page 19: ...nds to the time from stopped to reaching the maximum speed or from the maximum speed to stopped The inclines of the ramps are constant for each of the 8 ramps and independent of the set speed The refe...

Page 20: ...s are possible as long as a period of 10 s is not exceeded for steps 1 6 The configuration of a new start stop ramp runs in the following phases In steps 1 6 the master sends parameter values to the m...

Page 21: ...has stored the new start stop ramp and switched back to normal mode Contexts of module communication Note Sequence for command transmission For each step you generally send the data value via DO0 D03...

Page 22: ...rol module reaction 1 6 Incorrect data or parameter values or steps 1 6 take longer than 10 s Motor control module remains in normal mode 7 or 8 Incorrect data or parameter values The motor control mo...

Page 23: ...t AUX off AUX external power supply is miss ing Check AUX voltage and AUX flat cable AUX red on AUX external power supply is inverted Correct the polarity of the AUX flat cable in the cable guide AUX...

Page 24: ...Pepperl Fuchs Quality Download our latest policy here www pepperl fuchs com quality www pepperl fuchs com Pepperl Fuchs Subject to modifications Printed in Germany DOCT 6524A...

Reviews: