Troubleshooting
2
0
2
1
-0
5
23
6
Troubleshooting
Fault information and remedy
Error
LED status indi-
cator
Possible cause
Remedy
No data commu-
nication with AS-
Interface master
PWR off
AS-Interface voltage is missing or is
inverted
Check AS-Interface wiring
PWR flashes and
FAULT on
Module address is 0
Program module address
PWR on and
FAULT on
AS-Interface master is not switched
on (offline) or
There is duplicate addressing
Switch on the AS-Interface master
or
Check the addresses of all modules
on the AS-Interface segment
Motors do not
start
AUX off
AUX external power supply is miss-
ing
Check AUX voltage and AUX flat
cable
AUX red on
AUX external power supply is
inverted
Correct the polarity of the AUX flat
cable in the cable guide
AUX green on
and
FUSE1 (motor 1)
and/or FUSE2
(motor 2) off
Motor fuse is faulty due to overload
of the motor supply
Replace the motor control module
(cannot be repaired) and remove
the cause of the overload before
starting the motor again
PWR and FAULT
flash alternately
Peripheral fault "Overload speed
signal SPEED":
Motor, motor cable, or motor control
module is faulty
Replace motor or motor control
module
Sensors or
inputs IN1 ... IN2
not working
PWR and FAULT
flash alternately
Periphery fault: overload on sensor
supply
Check the sensors and eliminate
the overload
Table 6.1