Appendix
2
0
1
7
-0
6
69
Device parameters
User tag
192
R/W
char[32]
Operating hours 224
R
unit32
0.25h
Name
Index
(dec)
Sub-
index
Type
Data
type
Value
Default
value
Unit
Output Configuration
Switching output
–
Switch point 1
60
1
R/W
unit16
UC250: 20 ... 425
UC400: 30 ... 680
UC800: 60 ... 1200
UC250: 20
UC400: 30
UC800: 60
mm
Switching output
–
Switch point 2
60
2
R/W
unit16
UC250: 20 ... 425
UC400: 30 ... 680
UC800: 60 ... 1200
UC250: 20
UC400: 30
UC800: 60
mm
Switching output
–
Output logic
61
1
R/W
unit8
0x00: Normally open
0X01: Normally
closed
0x00
Switching output
–
Output mode
61
2
R/W
unit8
0x01: Switch point
mode
0X02: Window mode
0x03: Hysteresis
mode
0x80: Retroreflective
mode
0x02
Switching output
–
Switching
hysteresis
61
3
R/W
unit16
0x00: low
0x01: medium
0x02: high
0x00
Switching output
–
Retroreflective
mode offset
64
1
R/W
unit16
UC250: 1 ... 125
UC400: 1 ... 200
UC800: 1 ... 400
UC250: 12
UC400: 20
UC800: 40
mm
Switching output
–
Switch-off
delay
64
2
R/W
unit16
0 ... 60000
0
ms
Switching output
–
Switch-on
delay
64
3
R/W
unit16
0 ... 60000
0
ms
Switching output
- Output type
112
1
R/W
unit8
0x00: push-pull
0x01: sourcing (PNP)
0x02: sinking (NPN)
0x00
Analog output
–
Near limit
66
1
R/W
unit16
UC250: 20 ... 425
UC400: 30 ... 680
UC800: 60 ... 1200
UC250: 20
UC400: 30
UC800: 60
mm
Analog output
–
Far limit
66
2
R/W
unit16
UC250: 20 ... 425
UC400: 30 ... 680
UC800: 60 ... 1200
UC250: 250
UC400: 400
UC800: 800
mm
Analog output
–
Output type
114
1
R/W
unit8
0x00: Current
0x01: Voltage
0x00
Analog output
–
Output mode
114
2
R/W
unit8
0X00: Rising ramp
0X01: Falling ramp
0x00
Analog Output
–
Lower output
value (current)
114
3
R/W
unit8
0
200 (0...20mA)
40
0.1 mA
Name
Index
(dec)
Sub-
index
Type
Data
type
Value
Default
value
Unit