51
Radar Motion Sensor RMS-FRW
Appendix
Output hold time
In the case of the setting "Off", together with the function "Polarity - output", the door could remain open or closed
indefinitely.
This setting can be set using the remote control or the keypad menu.
Polarity
Using this function, it can be preset whether the output of the movement detector works with active or passive switch-
ing during detection.
This setting can be set using the remote control or the keypad menu.
Setting
Hold time
0
off (no output signal)
1
0.2 s
2
0.5 s
3
1 s
4
2 s
5
3 s
6
4 s
7
5 s
8
10 s
Output type
RMS-FRW with relay
RMS-FRW with voltage output
RMS-FRW with frequency output
Active
Relay contacts closed
at detection
Output voltage = on
at detection
Output frequency = on
at detection
Passive
Relay contacts open at detection
Output voltage = off
at detection
Output frequency = off
at detection