2
01
7-
11
12
Installation
Figure 3.1
Zero line for code tapes
If the reader leaves the zero line when traversing along the X-axis, the threshold may deviate. If
the deviation exceeds the defined threshold, a warning code is issued.
Y-Axis Deviation Thresholds
3.2
Mounting the Reader
Mounting the Reader
—
The Process
Make sure that you can mount the reader such that it has a stable position. Prior to mounting
the reader, make sure that the guidance of the moving system component is such that the
reader depth of focus range is not exited during operation.
1. Secure the reader to the moving component of your system via the four screws on the reader
mounting adapter.
2. Mount the reader
vertically
so that the lens with ring light and camera module are aligned
toward the code tape.
Figure 3.2
Vertical alignment tolerance
3. Alternatively, mount the reader
horizontally
so that the lens with ring light and camera
module are aligned toward the code tape.
Hysteresis Y-Axis
Code Tape
Threshold
Number of Tracks
Width
Exit
Entry
1
15 mm
±
29 mm
±
25 mm
Y
0
X
Read distance
Code tape
30° 30°