Installation
2
01
7-
11
11
Position the code tape so that the
FUCHS
logo and position markers are below the
data matrix code. The position values then increase along the X direction. The diagram shows
the orientation of a reader in the default setting of 0
°
. The reader can be configured in the
interface for other installation situations.
Code Tapes with a Starting Position of 0 m
Alignment of the Code Tape and Reader
Order Designation
Description
PXV00001-CA25-*
Code tape, 1-track, length: 1 m
...
...
PXV100000-CA25-*
Code tape, 1-track, length: 100,000 m
000 009.0 m P
XV-AA25
www.pepper
l-fuchs.com
Y
Z
X
Note!
Expansion Joints and Code Tapes
If the system covers longer distances, expansion joints are integrated in the system structure.
We recommend creating breaks along the code tape. The resulting gap must not exceed
75 mm.
Note!
Inclines and Declines
If you affix the code tape on inclines or declines, cut the code tape several times at the
transition point to the horizontal as shown.
1. Incline
2. Decline
000 009.0 m
000 009.0 m
1
2