Installation
Preparation
Unpacking the unit
1. Check that all package contents are present and undamaged. If
anything is damaged, inform the shipper and contact the supplier.
2. Check that all items are present and correct based on your order
and the shipping documents.
3. Keep the original packing material in case you need to store or
ship the unit at a later time
If you have any questions, please contact Fuchs.
Installation wiring
When connecting the barcode reader wiring to the SK-PC-D2
nonincendive barrier, please follow the tables below. The color coding
is based on the Fuchs cable accessories that are sold with the
PSCAN-D-1D-D2.
Field side barrier connection
SK-PC-D2-UN2-10-HS
SK-PC-D2-RN2-10-HS
Terminal
Wire Colo
r
Terminal
Wire Colo
r
V+
Brown
V+
Brown
D+
Blue
D+
Blue
D-
White
D-
White
V-
Black
V-
Black
PC side barrier connection
SK-PC-D2-UN2-10-HS
SK-PC-D2-RN2-10-HS
Terminal
Wire Colo
r
Terminal
Wire Colo
r
D+
Green
D+
Red (Tx)
D-
White
D-
Brown (Rx)
Ground
Black
Ground
Yellow
(Gnd)
NOTE:
Color codes are in reference to
Fuchs cable assemblies
Field side barrier connection
SK-PC-D2-UN2-10-HS
SK-PC-D2-RN2-10-HS
Cable length
15' (4.6 m)
Cable length
45' (13.7 m)
PC side barrier connection
SK-PC-D2-UN2-10-HS
SK-PC-D2-RN2-10-HS
Cable length
6' (1.8 m)
Cable length
45' (13.7 m)
Total distance (PC to barcode reader)
SK-PC-D2-UN2-10-HS
SK-PC-D2-RN2-10-HS
Cable length
18' (5.5 m)
Cable length
50' (15.2 m)
CH1 CH1 CH1 CH1
V+ D+ D- V-
PWR PWR GND GND
+ -
CH1 CH1
D+ D-
SK-PC-D2-xN2-10-HS
PC side
Field side
Status Indicators
The barcode reader has two indicator LEDs, a good read spot, and a
beeper. They signal several operating conditions that are described in the
following table.
H=
High tone
L=
Low tone
*=
Tone and intensity are user-configurable
#=
The data entry "good read tone" is user-configurable with
all beeper commands in the Reading Parameters section.
Start up
Beeper*
Meaning
LLLL
Parameter loading correctly
H H H H
long tones
Parameter loading error, reading, or writing error in the
nonvolatile memory
HLHL
Hardware error in EEPROM
Configuration
Beeper*
Meaning
HHHH
Correct entry or exit from configuration mode
L
Good read of a command
LLLL
Command read error
Reader data entry
Beeper*
LED Good
read spot
Meaning
One beep
On
On
Correct read of a code in normal mode
HL
TX buffer full (when FIFO is enabled)
H long
On
On
Successful advanced format
concatenation
HHHH
Timeout expired - operation not
completed
HH long
Error in advanced data formatting
Off
Off
Ready to read a code
On
Off
Ready to read a code