PSCAN-D-1D-D2 Division 2 Barcode Reader
53
Subject to modifications
www.pepperl-fuchs.us
USA: +1 330 486 0002
Singapore: +65 6779 9091
Copyright Fuchs
Germany: +49 621 776 2222
Exit and Save Configuration
ADVANCED FORMATTING
Ì$-?Î
112
2
Code 2
code ID
ÌEK1hÎ
Read the code type from the Code Identifier Table beginning in Appendix
B
.
code length
ÌEL1jÎ
Read a number in the range
01-99 from the Hex/Numeric Table.
3
Concatenation Result Code ID
use code 1 ID
ÌEN0kÎ
use code 2 ID
ÌEN1nÎ
Since you can concatenate codes from different families, you must select the Code ID character
of the resulting code. The Code ID character will be sent in the output message only if it is
enabled according to the Code Identifier selection (Datalogic, AIM, or Custom).
4
Concatenation Timeout
timeout
ÌEJ3Î
Read two numbers in the range
00 to 99
00= no timeout
01-99 = timeout from 1 to 99 seconds
Define the timeout, which determines the valid waiting period between the two codes, in order to
accept concatenation. If the timeout expires, the resulting action will be based on the following
selection. (HHDII)
, page 75.