2
0
2
1
-0
5
10
Product Description
CANopen-Status
LED operating mode indicator
LED fault indicator
Status indicator
Figure 2.4
"CAN Warning Limit reached
”
during "PREOPERATIONAL" State
Read head status
LED
1
2
Description
Color
green yellow
green red
State
off
off
x
x
Device is switched off.
off
blinking
x
x
The device is in the "PREOPERATIONAL" state
(before operation).
off
single
flash
x
x
The device is in the "STOPPED" state (stopped).
off
on
x
x
The device is in the "OPERATIONAL" state (in
operation).
LED
1
2
Description
Color green
yellow
green red
State
blinking
off
x
x
General configuration error
on
off
x
x
CANopen bus off
LED
1
2
Description
Color green
yellow
green red
State
2x blinking 1x blinking x
x
The read head is not accepted by the
CANopen master during the startup process in
"PREOPERATIONAL" status.
LED
1
2
Description
Color
green yellow
green
red
State
x
x
Lights up
Off
Code detected
x
x
Off
Flashing
Code not detected
x
x
x
Lights up
System error
x
x
Lights up, 1 s
Off
Codecard read
x
x
Off
Lights up, 1 s
Codecard not read
200
ms
200
ms
1000
ms
green on
(grün an)
yellow on
(gelb an)
off
(aus)