Optical data coupler LS611
Maintenance
8.3
Using C1CP
The function "C1CP" = Class1-Master Collision Protection can be added by keeping the
key pressed like in the baud rate selection (cf. chapter 7.1). If the LED is lit for C1CP, the
function is active.
In order to employ this protection effectively, it is recommended to set the addresses of
the Class2-Masters as high as possible, i.e. approx. > 80. At the same time, the highest
address "HSA" = Highest Station Address to be parameterized is set higher from the out-
set or at least equally high as the highest real address used. In case of longer aisles, the
perfect alignment is especially important. In case of longer distances, at least one green
LED of the bar graph indicator should be lit.
9
Maintenance
LS611 does not require any servicing. When dust/dirty (alarm, stability control), use a
moist cloth to wipe the plastic lenses and use a neutral detergent, if and when required.
Do not use any detergents containing alcohol or solvents.