201
7-0
2
24
Level Probe LGC2
Installation
5.6
Mounting the Terminal Box
The optional terminal box is mounted using four screws (M4).
5.7
Mounting the HUT Temperature Head Transmitter with Terminal
Box
Figure 5.5
Note!
To remove the cable mounting screw, perform this sequence of steps in reverse.
Warning!
Risk of injury from working on containers
Installation works on containers under pressure can result in injuries.
Only mount the device with cable mounting screw in unpressurized containers.
1
Mounting screws
2
Mounting springs
3
HUT temperature head transmitter
4
Circlips
5
Terminal box
1
3
2
6
5
4
3
CLOSE
90°
OPEN
90°
Warning:
Avoid electrostatic charge in explosive atmosphere.
See instructions
Term
inal B
ox
1
2
3
4
5
Note!
Only open the terminal box with a screwdriver.
Warning!
Explosion hazard when using the temperature head transmitter
The usage of temperature head transmitter in the hazardous area can result in explosion.
Do not use the HUT temperature head transmitter in the hazardous area.