Installation
2
0
1
8
-1
2
19
Assembling the mounting aid and attaching the device
To assemble the mounting aid and attach the optical data coupler to the
adjustment device, proceed as follows:
1. Place the adjustment device on the mounting bracket in the required direction
and tighten the two M4 nuts.
2. Screw in the central M6 fixing screw, but do not tighten it yet.
3. Hold the device above the adjustment device with the retaining feet
positioned over the openings.
4. With your free hand, squeeze the two front latches on the adjustment devices
together.
5. Click the device into the openings. Make sure that the retaining feet of the
device are engaged far enough that you can push the two latches outward
fully. To do this, push in the center of the device, applying some force from
above if necessary.
The latches will spring all the way outward again.