Table 5a Electrical Requirements (3
φ
, 60Hz)
PUMP
HP/KW
Voltage 3
φ
60 HZ
Full Load
Current (AMPS)
2 / 1.5
208, 230, 460, 575
7.5, 6.8, 3.4, 2.7
3 / 2.2
208, 230, 460, 575
10.6, 9.6, 4.8, 3.9
5 / 3.7
208, 230, 460, 575
16.7, 15.2, 7.6, 6.1
7.5 /5.6
208, 230, 460, 575
24.2, 22, 11, 9
Table 5b Electrical Requirements (3
φ
, 50Hz)
PUMP
HP/KW
Voltage 3
φ∅
50 HZ
Full Load
Current (AMPS)
2 / 1.5
380, 415
3.4, 3.1
3 / 2.2
380, 415
5.2, 4.7
5 / 3.7
380, 415
8.0, 7.1
Table 6 Media Quantities for CF Filters
Optional 5 Micron Media
Model CL Filter System
Fill Gravel
(Pails)
Unifill 475
Standard 10 Micron Sand
(Pails)
Unigran 85
Garnet
(Pails)
Unigran 55
Silica Sand
(Pails)
Unigran 85
18 2 2
2
0
24 3 4
4
0
30 6 7
7
0
36 10 9
5
4
42 15 12
6
6
*Note
: Quantities may change according to head size. Please check your inspection report for exact
amount. LOADING: Fill the filter one third full with water before loading. Load media in order
described on the data sheet taking care to distribute the lower fill material (if used) around the under
drain system filling all voids.
KEY
DESCRIPTION
PART
NUMBER
Filter Parts
6
Gauge Kit (Includes: 4 way cross, pressure gauge, air vent & petcock)
A-Z-VNT-GA-C/L-150
12
Top Manway Gasket
4 X 6
CL 12
G-GSKT-04X06-NE-OVAL
12
Top Manway Gasket
6 X 8
CL 18, 24 & 30
G-GSKT-06X08-NE-OVAL
12
Top Manway Gasket
11 X 15
CL 36 & 42
G-GSKT-11X15-NE-OVAL