Electronic Monitor Operations 

The US-1500 system includes an electronic monitor that alerts you 

when it is time to change your filter cartridges. Both filter cartridges 

should be changed at the same time to ensure that the monitor works 

properly. The monitor measures actual water usage and is powered 

by a single 9-volt battery.

How the Electronic Monitor Works

The filter cartridges in the US-1500 should be replaced every 1,000 

gallons. The electronic monitor uses a combination of lights and 

alarms to alert you at different stages during the life of the filter 

cartridges. The lights are visible on the front panel of the filter system, 

to the left of the blue reset button:

0-950 gallons 

No alarm. Green light flashes when water is turned on.

950-1000 gallons 

Alarm BEEPS ONCE when water is turned on. Yellow light flashes 

when water is on.

1000+ gallons

Alarm BEEPS TWICE when water is turned on. Red light flashes when 

water is on.

Low or Dead Battery

No alarm. No lights. Replace battery.

NOTE:

 Gallons used while battery is dead will register on meter when 

battery is replaced

NOTE:

 To extend battery life, any sequence that includes any beeps 

will not be repeated if water is turned on again in less than 15 minutes.

Reset Button

The blue reset button is located on the front panel of the system. 

This button should only be pressed during initial installation or when 

new filter cartridges are installed. After pressing and releasing 

the button, you will hear two beeps followed by a sequence of two 

green, two yellow, and two red lights. This combination of beeps and 

lights indicates that the system has properly reset the internal gallon 

counter.

Replacing the Battery

The battery should be replaced every time new filter cartridges are 

installed or after 12 months of operation, whichever comes first.

Replacing Battery and Filters at the Same Time:

Install new 9-volt battery as described in Step Eight: Installing the 

Battery on p. 4. Make sure to press blue reset button on front panel of 

system when finished.

Replacing Battery Only:

Remove the old battery and install the new battery. DO NOT press the 

reset button on the front panel of the system when finished.

Filter Cartridge Replacement

•   Filter cartridges the US-1500 will last about 1,000 gallons or twelve 

months before they need to be replaced. Filter cartridge life 

varies depending on usage, and/or water conditions. Changes in 

taste, color, and flow of the water being filtered indicate that the 

cartridge should be replaced.

•  Read all instructions before replacing filter cartridges. 
1.   Turn off cold water supply and open the drinking water faucet to 

release pressure from system.

2.   Unscrew and remove bottom of filter housing. Locate and remove 

large O-ring, wipe clean of lubricant, and set aside. Repeat for 

second housing.

3.   Discard used filter cartridges. Using a non-abrasive sponge or 

cloth, scrub the bottom of filter housings, O-ring grooves, and 

caps with dish soap and warm water. Rinse thoroughly. Fill bottom 

of each housing 1/3 full with water. Add 1 tablespoon of household 

bleach and scrub to disinfect. 

4.   Lubricate O-rings with silicone grease. Insert each O-ring in 

groove and press into place. 

 

 

NOTE:

 This step is important to ensure a proper housing seal. 

Make certain each O-ring is seated level in its groove or a leak 

may occur. 

5.   Screw bottom of housings with bleach water onto caps without 

filter cartridges and hand-tighten. DO NOT OVERTIGHTEN. 

6.   Turn on water supply. Let faucet run for about 10 seconds, then 

turn off faucet and let stand for 20-30 minutes. 

7.   Turn on faucet and allow bleach water to run out (about 3-5 

minutes).

8.   Turn off water supply to system and open faucet to release 

pressure. Remove bottom of housings and empty of water. 

9.   Insert each filter cartridge in bottom of appropriate filter housing: 

P-250 Cartridge Set: white with green end caps in left housing, 

gray plastic cartridge in right housing

 

 

NOTE:

 The filter cartridges should be installed with the black 

gasketed ends pointing up.  

10.   Screw bottom of housings onto caps and hand-tighten. DO NOT 

OVERTIGHTEN. Make certain cap standpipe slips into cartridge. 

11.   Open water supply and turn on drinking water faucet to release 

pressure in system. Let faucet run for 5 minutes to remove trapped 

air and carbon fines. Check system for leaks before leaving 

installation. 

NOTE:

•   It is recommended that you run the tap at least 20 seconds prior to 

using water for drinking or cooking purposes.

•   Initially, filtered water may appear cloudy. If you set a glass 

of water on a level surface, you should be able to watch the 

cloudiness disappear from the bottom of the glass upwards. 

This harmless cloudiness results from the release of trapped air 

within the cartridge and will disappear within a few weeks after 

installation.

5

Summary of Contents for US-1500

Page 1: ...ty glasses Hand or electric drill cordless recommended 1 4 drill bit File Phillips head screwdriver Adjustable wrench or 7 16 open end wrench Tube cutters or utility knife If sink does not have hole f...

Page 2: ...o accommodate the faucet CAUTION This procedure may generate dusts which can cause severe irritation if inhaled or come in contact with the eyes The use of safety glasses and respirator for this proce...

Page 3: ...UTION Do not bend or crimp tube when inserting B Gently pull back on the tube to ensure it is connected properly If the tube comes out of tting cut a small section of the tube off and reconnect 6 Conn...

Page 4: ...t of guide arrows approximately 5 8 16 mm 8 Installing the Battery A Remove cover on top of system Attach 9 volt battery included to connector then place battery in holder located to the left of the m...

Page 5: ...e they need to be replaced Filter cartridge life varies depending on usage and or water conditions Changes in taste color and ow of the water being ltered indicate that the cartridge should be replace...

Page 6: ...8 and reinstall per Step Six Connecting the Supply Adapter Reconnect tubing or tighten compression nut with ngers then tighten nut snugly 1 2 turn with wrench Turn on water supply valve and check for...

Page 7: ...to manufacturer s instructions including replacement of lter cartridges Test Conditions Flow Rate as noted for lter system Inlet Pressure 60 psi 4 1 bar pH 7 5 1 Temperature 68 F 5 F 20 C 2 5 C Operat...

Page 8: ...erial Number if any and a brief description of the problem TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW PENTEK DISCLAIMS ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED...

Reviews: