8
z
The PowerTopoLite manual mainly describes the
R
-200 special functions, and the basic
operations are described in the (basic)
R
-200 manual. And, therefore, refer to the
R
-200 basic
manual regarding the
R
-200 general instrument operations.
The PowerTopoLite screens vary with the selections of the “Preference”. The factory default
settings of the Preference are shown there. It is also possible to select “Process type” that took
over functionality of “PowerTopoLite” or “Structure type” that took over functionality of our past
product in ”Action Method Selection”.
z
The
R
-200 series instrument has a Job name of “PENTAX” as its default setting. And, therefore,
each data is stored in the “PENTAX” unless another new Job name is created. When another
Job name is created, each data is stored in the new Job name.
z
The input range of the X, Y and Z Coordinate is “-99999999.998” – “99999999.998”.
z
The input range of the Instrument and Prism height is “-9999.998” – “9999.998”.
z
The PC, PointCodeList, is added to the PN, Coordinates X, Y, Z and IH (PH or HI) and you can
input your desired attributes for the point. If you have PointCodeList in the job named
“PointCodeList”, you can easily select one of the PointCode from the list or edit one of them
after pressing [ENT]. Please, note that Point Code, which is saved in the other job can not be
refered as a list.
z
There are two Coordinates types of Rectangular and Polar. The VO, TO offset and the remote
measurement are possible when you select the Rectangular Coordinates.
z
When you measure in EDM SETTINGS of COARSE TRACKING, the
R
-200 displays a distance
value to two decimal places. However, distance data of polar coordinates are displayed by EDIT
function to three decimal places even, and sent to four decimal place. So, “ 0 “ or “ 00 ” is
added to the distance data after the third decimal point in COARSE TRACKING mode.
For example
Displayed value: 123.45
Displayed by EDIT: 123.450
Sent polar data: 123.4500
z
Rectangular coordinates is displayed, stored, and sent to three decimal place even if in
COARSE TRACKING or FINE MEASURE mode.
z
You can change the distance measurement mode during measuring operation by pressing the
EDM key at the
MEASURE
and VPM functions.
z
The same Point Name of the plural polar points can be saved.