93
With PTL, "POLAR DATA" can be transferred by "DC1" or "AUX" format.
In addition, it is possible DL-01 to receive/convert “POLAR DATA “with” DC1 (DC-1Z) format.
b-2 Notes for unit.
If you are requested to select unit when you convert data on DL-01, please select unit
according to the settings on R-200 series.
b-3 Limitation for each format.
Please, use "CSV" or "DC1( DC-1Z) " format to transfer data to/from R-200 series.
Limitation for the "CSV" format.
With the "CSV" format, "PN" and "PC" (Point Code) data consist of less
or equal to 15 (one-byte) characters can be transferred.
Limitations for the "DC1 (DC-1Z)" format.
With "DC1 (DC-1Z)" format, the length of "PN" data should consist of less
or equal to 11 (one-byte) characters. And with the "DC1 (DC-1Z)" format
"PC" data cannot be transferred.
b-4 Recommended communication settings on R-200 series.
Recommended settings for "COMM SETTING SELECTION" on R-200 series special
function is as follows.
R-200 series
PC(DL-01) to "SEND RECT. DATA"
1.BAUD RATE:
1200
2.DATA LENGTH:
8
3.PARITY BITS:
NIL
4.STOP BITS:
1
5.SIGNAL CONTROL:
OFF
6.XON/XOFF:
OFF
7.PROTOCOL:
OFF for "CSV" format, ON for "DC1 (DC-1Z)" format
8.RECORD DELIMETER: CR+LF
Subsequent items:
As you like.
R-200 series
PC(DL-01) to "SEND POLAR DATA"
1.BAUD RATE:
1200-9600
2.DATA LENGTH:
8
3.PARITY BITS:
NIL
4.STOP BITS:
1
5.SIGNAL CONTROL:
OFF
6.XON/XOFF:
OFF
7.ROTATION:
As
you
like.
PC(DL-01) R-200 series
to "RECEIVE RECT. DATA"
1.BAUD RATE:
1200
2.DATA LENGTH:
8
3.PARITY BITS:
NIL
4.STOP BITS:
1
5.SIGNAL CONTROL:
OFF
6.XON/XOFF:
OFF
7.PROTOCOL:
OFF for "CSV" format, ON for "DC1 (DC-1Z)" format
8.RECORD DELIMETER: CR+LF
9. Subsequent items:
As you like.
Please note that these settings should be common with DL-01's.
b-5 Recommended communication settings on DL-01.
To configure DL-01 Communication setting, please read "Configuring the
software" in the Help topics of DL-01. And select values as follows.
For setting “Type of Device” in the "Settings" panel (Menu—“Edit”--”Settings”),
select “R-100 (PTL) / R-300(PTL)” and other setting should be as follows.