background image

76670  -7/12- 

4. ADJUSTMENT THE PROGRAM SOFT    (SLR function) 

Caution: When replaced T100, the following procedure should be completed 
Preparation

   

Programmed software for 76670 (for SLR operation), USB cable (I-USB17) 
Computer (Windows 2000 / XP), AC-adaptor (D-AC10), Light source (Shutter tester) 
Temporary bottom cover (Hand made/exclusive item), Power supply (8V,3A)

 

Shutter tester (1/4000 can be measured), Diaphragm set ring F8 (KA-0-1A), FA (F) 35-80mm F4-5.6, 
AF positioning jig (Square) for 27830, AF positioning jig (Cross) for 27250, Power adaptor, 
AF chart for 2m x2 (Exclusive item), AF master lens for 2m, FA Macro 50mmF2.8, 
Driver1.5mm (HD-M1.5)

 

 

4-1. SETTING THE COMPUTER 

z

 

Setting the computer (Page2) and 

Set up the VB run time (Page3) 

should be 

completed

 

 
 

4-2. Preparation 

When replaced T100 or CCD, the CCD ID number will be used 
for digital adjustment   

 

Install battery cover for battery adaptor and temporally bottom cover   

to the camera   

 

Set focus mode lever to [MF] 

 
4-3. DISPLAY FOR ADJUSTMENT 

When start the adjustment software, the following display will be opened 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

76670 SLR

A. Tool Bar

C. 

Menu display

 

Adjustment items

Product number

Menu Bar

B. USB connecting display

76670 

Summary of Contents for 76670

Page 1: ...PENTAX Service Co Ltd Technical Service Dep 04 06 KN PRODUCT No 76670 TM ENGLISH ...

Page 2: ... 2 2 Chart for Assemble Adjustment and Confirmation 6 3 DISASSEMBLY AND ASSEMBLY PROCEDURES 4 ADJUSTMENT THE PROGRAM SOFT SLR function 6 4 1 Setting the computer 4 2 Preparation 4 3 Adjustment display 4 4 Items for Adjustment and checking 4 5 Procedure for adjustment 4 6 Procedure for ending the program soft 5 ADJUSTMENT THE PROGRAM SOFT Digital function 5 1 Procedure for adjustment 7 7 7 8 9 11 1...

Page 3: ...Connect to PC Preparation for SD memory card 1 Two SD memory card for FW The following SD card is common use with istDL istDS 2 For SW test 3 For Test mode ON 4 For test mode OFF 5 For initial set 1 2 Setting the computer and copy the adjustment file to SD card 1 Copy the 76670 SLR folder from the Programmed software contained in the CD ROM to C drive as shown in the picture below For SLR adjustme...

Page 4: ...VisualBasic software set up the VB run time is required as follow Procedure Set the 76670 adjustment program soft into the computer Execute the setup exe in the folder of vb6run_csx x x Installer will be started The Execute file and uninstall setting file will be generated ...

Page 5: ...76670 4 12 Click OK Do not click Directory Click installation button ...

Page 6: ...76670 5 12 Set up will be started Click OK to end the installation ...

Page 7: ...will be required Same as istDS2 76640 2 2 Chart for Assemble Adjustment and Confirmation Procedure of Adjustment and confirmation is same as ist DL 76570 Refer to the ist DL 76570 Service manual 3 Procedure for Disassemble Assembly Procedure of Disassemble Assembly is same as ist DL 76570 FW for new T100 FW for service Adjustment ...

Page 8: ...0 AF positioning jig Cross for 27250 Power adaptor AF chart for 2m x2 Exclusive item AF master lens for 2m FA Macro 50mmF2 8 Driver1 5mm HD M1 5 4 1 SETTING THE COMPUTER z Setting the computer Page2 and Set up the VB run time Page3 should be completed 4 2 Preparation When replaced T100 or CCD the CCD ID number will be used for digital adjustment Install battery cover for battery adaptor and tempor...

Page 9: ...the data 2 Exposure adjust Adjustment of exposure BV adjust brightness value Adjustment of measurement sensor 3 AF and related adjust Adjustment of AF CCD position adjust Adjustment of CCD position AGC level adjust Adjustment of AGC level Uniformity adjust Adjustment of uniformity Focus offset adjust Adjustment of AF focus Op Start the correspond with Camera Cl Close the correspond with Camera p s...

Page 10: ...reen will be displayed Click Op to start correspond Confirmation Connect should display as follow Execute the check adjustment following the display screen as follows 1 EEPROM CHECKING 2 EXPOSURE ADJUST BV ADJUST Tools Focus master lens for 35mm KML 01 Diaphragm set ring F8 KA 0 1A Light source LV6 LV8 LV12 LV15 or LV6 LV9 LV12 LV16 3 AF AND RELATED ADJUST Tools AF positioning jig Square for 27830...

Page 11: ...NG When finished all adjustment click 5 EEPROM CHECKING When replaced T100 the following adjustment should be done additionally 6 BATTERY LEVEL ADJUST Tools Battery adaptor Power supply 8V 3A Follow the screen When open and close the battery cover Pc will be displayed in the LCD panel of the camera Click Op and then start the correspond with camera Display will change to Press BC Adjust and execut...

Page 12: ...top and then follow safe removal of hardware PENTAX USB DISK Device Turn the power of the camera OFF and remove AC adaptor USB cable Battery cover and temporally bottom cover can be stayed for next adjustment 5 ADJUSTMENT THE PROGRAM SOFT Digital part 5 1 The procedure is same as 76570 except following adjustment procedure When the setting and connecting is ready start the SLR MTest exe in the CSA...

Page 13: ...t file to SD card page 2 7 List of service equipments tools for istDL2 Ordering No Exclusive use for 76670 istDL2 Program soft for 76670 SLR Digital Supply with CD ROM No 95901 P407 For other equipments and tools are common use with istDL 76570 please refer to the service manual for istDL 76570 But the following tools are no need for istDL2 76670 Camera multi adaptor II or A Connecting cable for 2...

Reviews: