76670 -7/12-
4. ADJUSTMENT THE PROGRAM SOFT (SLR function)
Caution: When replaced T100, the following procedure should be completed
Preparation
:
Programmed software for 76670 (for SLR operation), USB cable (I-USB17)
Computer (Windows 2000 / XP), AC-adaptor (D-AC10), Light source (Shutter tester)
Temporary bottom cover (Hand made/exclusive item), Power supply (8V,3A)
Shutter tester (1/4000 can be measured), Diaphragm set ring F8 (KA-0-1A), FA (F) 35-80mm F4-5.6,
AF positioning jig (Square) for 27830, AF positioning jig (Cross) for 27250, Power adaptor,
AF chart for 2m x2 (Exclusive item), AF master lens for 2m, FA Macro 50mmF2.8,
Driver1.5mm (HD-M1.5)
、
4-1. SETTING THE COMPUTER
z
Setting the computer (Page2) and
Set up the VB run time (Page3)
should be
completed
4-2. Preparation
When replaced T100 or CCD, the CCD ID number will be used
for digital adjustment
①
Install battery cover for battery adaptor and temporally bottom cover
to the camera
②
Set focus mode lever to [MF]
4-3. DISPLAY FOR ADJUSTMENT
When start the adjustment software, the following display will be opened
76670 SLR
A. Tool Bar
C.
Menu display
Adjustment items
Product number
Menu Bar
B. USB connecting display
76670