76670 -10/12-
※
2m AF chart have to be set as follows
1
)
Distance between chart and mount of camera --- 1,954.5mm
(=
1.9545m
)
2
)
Chart should be set at perpendicularly against light axis of the lens
↓
[CCD POSITION ADJUST]
ADJUSTMENT
1) Alpha-CROSS --
→
- Dump Start --
→
Adjustment --
→
Stop
2) Beta-SQUARE --
→
- Dump Start --
→
Adjustment --
→
Stop
3) Focus --- Start -
→
- Next
→
Stop
→
Close
* When replaced M100, Click M100 button and then start adjustment
↓
POSITION CHECK
[AGC LEVEL ADJUST]
[UNIFORMITY ADJUST]
[FOCUS OFFSET ADJUST]
TEMP ADJUSTMENT
(
Select /F
→
Input temperature
→
Temp Adjust
→
Close
)
HORIZONTAL
・
VERTICAL*
(
START
→
Adjust position of chart
→
STOP
→
ADJUST
→
Close
)
5
:
EEPROM CHECKING
When finished all adjustment, click 5
:
EEPROM CHECKING
* When replaced T100, the following adjustment should be done additionally
6
:
BATTERY LEVEL ADJUST
Tools: Battery adaptor, Power supply (8V, 3A)
①
Follow the screen
When open and close the battery cover, [Pc] will be displayed in the LCD panel of the camera
②
Click Op and then start the correspond with camera. Display will change to
「
- - -
」
③
Press BC Adjust and execute the adjustment
④
After finished the adjustment, press Close button
※
If the power turned ON again, execute above
②
7
:
SHUTTER SPEED ADJUST
Tools: Shutter tester
①
Select the shutter tester
②
Press
RELESE
button and release the shutter several times, also measure the data
③
Input Measurements data and press
Input Data
④
After finished the adjustment, press
Close
button
Finish the [5
:
EEPROM CHECKING] and execute [End procedure]