[65] observing correct polarity.
Close the housing fully so that it clicks to. The detector is now in
operating mode.
Test the detector from the proposed position, a detection will be
indicated by the LED [60].
The remote control in the set is already enrolled to the panel and is
operational since the battery is already installed.
The detectors can be set according to the position of jumpers which connect
two pins together.
jumper connected
jumper not connected
Immediate
immediate alarm in full and
alarm
part arm
delayed alarm
delayed alarm in full and part
arm*
Home mode
immediate alarm by full arm,
no alarm in part arm
* If the delay in the panel is not activated (delay = 0 seconds) a delayed
detector will give an immediate alarm.
All functions are described in chapter 7.
LED active (LED indicates a detection and low
battery)
LED deactivated
Switch the power switch [19] to the OFF position.
If required connect any optional wired accessories (see chapter 16)
Switch the power switch to the ON position.
Close the cover [28] so that the cable protrudes through the top middle.
!
!
!
!
!
!
9.4 Remote control 3000R
10.1 ZONE jumper [58/64] (3000P, 3000M)
10.2 LED jumper [57] (3000P)
11.1 Panel 3000Z
10. Setting the detectors
11. Installation
Remove batteries before changing the jumper positions.
D0 D1 D2 D3
setting
reaction
OFF
ON
Factory default: delayed alarm
factory default: LED on
{
{
{
{
{
{
{
{
{
{
{
{
{
{
{
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
Wall mounting
Table use
when the stand is used
Note:
Mark the position for the screw holes through the screw holes [26]
onto the wall.
Drill the fixing holes and insert the wall plugs [31].
Fix the bracket to the wall with the screws [30].
Hang the panel with the keyhole slots [17] over the bracket
Hang the panel over the with the keyhole slots [17] onto the stand.
Connect the mains adapter with the mains outlet.
When the panel is on the bracket or the stand the tamper switch [16] is
depressed. If the panel is moved
it will not activate a
tamper alarm.
Mark the fixing positions on the wall through the fixing holes [51] of the
bracket [50].
Drill two holes and insert the wall plugs [55].
Fix the bracket with screws [54] to the wall.
Press the ball joint [53] into the bracket.
Slide the bracket into the slot [44] on the back of the detector.
Position the detector such that it is vertical, not tilted, and the LED [43]
is beneath the lens.
Remove the protective film from one side of the adhesive pads [63].
Attach the pads to the middle of the rear housing of the magnet [62]
and sensor [59].
Remove the foil from the other side of the pads.
Fix the magnet vertically on the window/doorframe directly next to the
window/door edge. Attach the sensor so that the arrows are level,
leaving a maximum gap of 10mm in closed condition (see Fig. E and G).
If the window frame is thick, attatch the magnet to the edge of the frame to
ensure a maximum gap of 10mm (see Fig. H).
The factory default language for SMS is German. Change to English as
follows:
1. Send an SMS with text "5" to the panel SIM card.
2. The panel answers with following SMS:
11.2 PIR-detector 3000P
11.3 Door/window contact 3000M
The contact will not operate on the hinged side.
12. Operation
TEL:
1.
2.
3.
4.
5.
3. Using the function “Forward” (or “Edit” on older mobile phones) enter
into the SMS the required phone numbers (without any spaces) eg:
40