During disarmed status the system monitors the detectors. If a battery
compartment lid is removed, eg. a from contact is removed from the
door frame, then the detector sends tamper alarm signal to the panel.
14. Settings
The system is factory set as follows:
delay for delayed detectors
30 seconds
delay for other detectors
0 seconds (=immediate alarm)
volume of panel siren
2 (normal)
alarm period
3 minutes
user code
1 2 3 4
language
German*
key tone
activated
* to change the language see chapter 12
Settings can be changed and set only by sending SMS commands from the
numbers stored with SMS "5" and “6” to the number of SIM card in the
panel. The SMS commands can also be send using the Application (App see
side 1). Further SMS command texts are listed in chapter 12.9.
A detailed description of the operation via SMS can be found
on the sheet enclosed.
SMS text
command
reaction
00
status enquiry
status and settings sent by SMS
?
Enquiry menu 1
first menu side sent by SMS (SMS 0 /
1 / 2 / 3 / 4 / 00 / ??)
??
Enquiry menu 2
second menu side sent by SMS
(SMS 5/6/7/8/???)
???
Enquiry menu 3
third menu side sent by SMS
(SMS 91-99/101- 104 / 11 / 12 / 13
/ 14)
5*
store numbers
per SMS enter max. 5 numbers for
for alarm calls
setting and for receiving alarm calls
6*
store numbers
per SMS enter max. 5numbers for
for alarm SMS
setting and for receiving alarm SMS
(no. Stored as “1." will be sent SMS
upon mains power failure)
7*
store number
per SMS enter 1 number which
to receive SMS
receives
SMS for disarm
with RFID
for RFID disarm
tag**
8*
Preset number
per SMS enter 1 preset number
91-99*
name detectors
per SMS name detectors 1 to 9
1-9
(for detectors 10 to 50 the text
remains: detector X Alarm)
101-104*
SMS text
per SMS enter SMS text (max. 30
for RFID disarm
tokens), to be sent when
disarming
with the first 4 enrolled
RFID tags**
11*
delay for other
per SMS enter the entry/exit delay
detectors
(0 to 300 seconds - usually leave as
factory default=0)
12*
volume and
per SMS enter values
period of alarm
(volume: 0 = off, 1 = quiet, 2=
normal; period: 1 to 9 minutes)
13*
change user code
per SMS enter new user code
14*
delay for delayed
per SMS enter delay
detectors
(0 to 300 seconds, 0= no delay)
21
delete all detectors per SMS delete all wireless
detectors
22
delete all RFID tags per SMS deleteall RFID tags
23
delete all remote
per SMS delete all remote controls
controls
30
deactivate key tones per SMS deactivate the key tones
31
activate key tones
per SMS activate the key tones
0000
Reset
all settings back to factory default ***
0001
English
per SMS set the SMS language to
English
* for all commands marked * the SMS received from the panel must be
edited and then forwarded to the panel, in order to store the
changes/settings. The successful change/setting will be confirmed by
SMS.
Note: Do not use spaces while editing and forwarding the SMS.
** to enable this function both the settings SMS "7" and SMS "101-104”
must be completed
*** a reset can also be made by pressing the tamper switch
[16] 5 times within 3 seconds.
Example: store numbers for alarm SMS
42
6
send SMS
:
SMS:
1.
2.
3.
4.
5.
SMS:
1. 67890033
2. 67890022
3. 67890011
4. 67890000
5.
Store alarm SMS No.
successfully.
Edit the received SMS and then forward it
Note:
Do NOT insert any space or any “+”
symbol before the number (enter
eg.0049...)