background image

Maintenance (Continued)

10. Remove slinger from motor shaft

and inspect for damage or
abrasion.

11. Clean seal cavity in seal plate and

clean motor shaft.

PUMP REASSEMBLY/INSTALLING
NEW SEAL

1. Ceramic seat must be clean and free

of dirt, grease, dust, etc. Wet outer
edge with small amount of liquid
detergent; press ceramic seat into

seal plate cavity firmly and squarely
with finger pressure (See Figure 6).

2. If ceramic seat will not locate

properly, remove it, place 

face up

on bench and reclean cavity.
Ceramic seat should now locate.

3. If seat still will not locate properly,

place a cardboard washer over the
polished face and use a piece of
3/4" (19mm) standard pipe for
pressing purposes.

NOTE: 

Be sure not to scratch or mar

polished surface or seal will leak.

4. Replace slinger on end of motor

shaft so that impeller sleeve will
push it into position. If slinger
shows signs of wear or damage,
replace it.

5. Remount seal plate on motor.

Tighten bolts to 60-80 inch-lbs. 
(69-92 kg/cm) torque.

6. Apply a 

small

amount of liquid

detergent to inside diameter of
rotating half of seal.

7. Slide rotating seal member, 

polished carbon face out, over
impeller sleeve until rubber drive
ring hits back of impeller.

NOTE: Be sure

not to nick or scratch

polished seal face; seal will leak if face
is damaged.

8. Screw impeller onto shaft

(clockwise); this will automatically
locate seal in seal plate.

NOTE: 

On 2 and 2

1

2

HP models; install

impeller gasket and lock screw (left-
hand thread - turn counterclockwise).
Torque lock screw to 50-55 inch-lbs.
(57.6-63 kg/cm).

9. Mount diffuser on seal plate;

tighten screws to 10-14 inch-lbs.
(11.2-16.1 kg/cm) torque.

10. Assemble motor and seal plate to

pump body with nuts, flat washers,
and lock washers. Torque nuts to
120-130 in-lbs. (138-150 kg/cm).

11. Prime pump according to

instructions on Page 5.

Models 4RJ93, 4RJ94 and 4RJ95

7

Teel Operating Instructions and Parts Manual

®

E

N
G

L

I

S

H

Figure 6

Polished
surface

Rubber
surface

Limited Warranty

DAYTON ONE-YEAR LIMITED WARRANTY.

Teel

®

pool pump with integral trap, Models covered in this manual, are warranted by Dayton Electric Mfg. Co.

(Dayton) to the original user against defects in workmanship or materials under normal use for one year after date of purchase. Any part which is determined
to be defective in material or workmanship and returned to an authorized service location, as Dayton designates, shipping costs prepaid, will be, as the
exclusive remedy, repaired or replaced at Dayton’s option. For limited warranty claim procedures, see PROMPT DISPOSITION below. This limited warranty gives
purchasers specific legal rights which vary from jurisdiction to jurisdiction.

LIMITATION OF LIABILITY.

To the extent allowable under applicable law, Dayton’s liability for consequential and incidental damages is expressly disclaimed.

Dayton’s liability in all events is limited to and shall not exceed the purchase price paid.

WARRANTY DISCLAIMER.

Dayton has made a diligent effort to provide product information and illustrate the products in this literature accurately; however,

such information and illustrations are for the sole purpose of identification, and do not express or imply a warranty that the products are MERCHANTABLE, or
FIT FOR A PARTICULAR PURPOSE, or that the products will necessarily conform to the illustrations or descriptions.
Except as provided below, no warranty or affirmation of fact, expressed or implied, other than as stated in the “LIMITED WARRANTY” above is made or
authorized by Dayton.

PRODUCT SUITABILITY.

Many jurisdictions have codes and regulations governing sales, construction, installation, and/or use of products for certain purposes,

which may vary from those in neighboring areas. While Dayton attempts to assure that its products comply with such codes, it cannot guarantee compliance,
and cannot be responsible for how the product is installed or used. Before purchase and use of a product, review the product applications, and all applicable
national and local codes and regulations, and be sure that the product, installation, and use will comply with them.
Certain aspects of disclaimers are not applicable to consumer products; e.g., (a) some jurisdictions do not allow the exclusion or limitation of incidental or
consequential damages, so the above limitation or exclusion may not apply to you; (b) also, some jurisdictions do not allow a limitation on how long an implied
warranty lasts, consequently the above limitation may not apply to you; and (c) by law, during the period of this Limited  Warranty, any implied warranties of
implied merchantability or fitness for a particular purpose applicable to consumer products purchased by consumers, may not be excluded or otherwise
disclaimed.

PROMPT DISPOSITION.

Dayton will make a good faith effort for prompt correction or other adjustment with respect to any product which proves to be

defective within limited warranty. For any product believed to be defective within limited warranty, first write or call dealer from whom the product was
purchased. Dealer will give additional directions. If unable to resolve satisfactorily, write to Dayton at address below, giving dealer’s name, address, date, and
number of dealer’s invoice, and describing the nature of the defect. Title and risk of loss pass to buyer on delivery to common carrier. If product was damaged
in transit to you, file claim  with carrier.

Manufactured for Dayton Electric Mfg. Co., 5959 W. Howard St., Niles, Illinois 60714  U.S.A.

Summary of Contents for Teel 4RJ93

Page 1: ...this symbol on your system or in this manual look for one of the following signal words and be alert to the potential for personal injury Warns about hazards that will cause death serious personal inj...

Page 2: ...icing pump and piping NOTE When connecting threaded pipe directly to pump use Teflon tape or Plasto Joint Stik1 to seal connections Do not use pipe dope pipe dope causes cracking in some plastics and...

Page 3: ...ystem must be six feet per second or less even if one main drain suction fitting is com pletely blocked The flow through the remaining main drain s must comply with the latest ASME ANSI Specifi cation...

Page 4: ...walls of swimming pool spa or hot tub WIRING Pump must be permanently connected to circuit The Wiring Chart below gives correct wire and circuit breaker sizes for the pump alone If other lights or ap...

Page 5: ...Clean and inspect O Ring reinstall on trap cover Replace trap cover on trap turn clockwise to tighten cover NOTE Tighten trap cover by hand only no wrenches Pump should prime now Priming time will dep...

Page 6: ...wer to motor before working on pump or motor Aside from lubricating trap cover O Ring no lubrication or regular maintenance is needed beyond reasonable care and periodic cleaning of strainer basket If...

Page 7: ...tion to jurisdiction LIMITATION OF LIABILITY To the extent allowable under applicable law Dayton s liability for consequential and incidental damages is expressly disclaimed Dayton s liability in all...

Page 8: ...94 WG 17 16 18 19 20 21 22 23 15B 1 2 3 4 5 6 7 8 8A 8B 9 10 See Box A Se Bo 11 12 13 14 15A Please provide following information Model number Serial number if any Part description and number as shown...

Page 9: ...85P C3 185P C3 185P 1 13 Trap cover O Ring U9 375 U9 375 U9 375 1 14 Trap basket C8 58P C8 58P C8 58P 1 15A Drain plug U178 920P U178 920P U178 920P 2 15B 5 16 14 x 5 8 Mounting screw 2 16 Base C4 77P...

Page 10: ...rap and strainer trap or impeller 2 Impeller is clogged 2 Check impeller for clogging Follow steps 1 trough 7 under Removing Old Seal Page 6 Follow steps 7 through 11 under Installing a New Seal Page...