background image

Models 4RJ93, 4RJ94 and 4RJ95

3

Teel Operating Instructions and Parts Manual

®

E

N
G

L

I

S

H

Installation (Continued)

ENTRAPMENT PROTECTION

The pump suction system must provide
protection against the hazard of
suction entrapment or hair
entrapment/entanglement.

SUCTION OUTLET COVERS

All suction outlet covers must be
maintained. They must be replaced if
cracked, broken, or missing. 

See below for outlet cover certification
requirements.

All suction outlets must have correctly
installed, screw-fastened covers in place.

OUTLETS PER PUMP
(FIGURE 1)

Provide at least two hydraulically
balanced main drains, with covers, for
each swimming pool pump suction
pipe. The centers of the main drains
(suction fittings) must be at least three
feet apart. 

The system must be built so that it
cannot operate with the pump
drawing water from only one main
drain (that is, there must be at least
two main drains connected to the
pump whenever it is running).

However, if two main drains run into a
single suction pipe, the single suction
pipe may be equipped with a valve
which will shutoff both main drains
from the pump.

More than one pump can be
connected to a single suction pipe as
long as the requirements above are
met.

WATER VELOCITY

The maximum water velocity through
any suction outlet must be 1.5 feet per
second unless the outlet complies with
the latest ASME/ANSI Specification for
Suction Fittings For Use in Swimming
Pools, Spas, Hot Tubs, and Whirlpool
Bathtub Applications. 
In any case, do
not exceed the suction fittings
maximum designed flow rate.

If 100% of the pump’s flow comes
from the main drain system, the
maximum water velocity in the pump
suction hydraulic system must be six
feet per second or less even if one
main drain (suction fitting) is com-
pletely blocked. The flow through the
remaining main drain(s) must comply
with the latest ASME/ANSI Specifi-
cation for Suction Fittings For Use in

Swimming Pools, Spas, Hot Tubs, and
Whirlpool Bathtub Applications.

TESTING AND CERTIFICATION

Suction outlet covers must have been
tested by a nationally recognized
testing laboratory and found to
comply with the latest ASME/ANSI
Specifications for Suction Fittings For
Use in Swimming Pools, Spas, Hot
Tubs, and Whirlpool Bathtub
Applications.

FITTINGS

Fittings restrict flow; for best efficiency
use fewest possible fittings.

Avoid fittings which could cause an air
trap.

Pool fittings must conform to
International Association of Plumbing
and Mechanical Officials (IAPMO)
standards.

Use only non-entrapping suction
fitting or double suction.

Electrical

Ground motor
before connecting

to electrical power supply. Failure to
ground motor can cause severe or fatal
electrical shock hazard.

Do not ground to a gas supply line.

To avoid dangerous or fatal

electrical shock, turn OFF power to

motor before working on electrical
connections.

Ground Fault Circuit Interrupter

(GFCI) tripping indicates an

electrical problem. If GFCI trips and will
not reset, have a qualified electrician
inspect and repair electrical system.

Exactly match supply voltage to

nameplate voltage. Incorrect

voltage can cause fire or seriously
damage motor and voids warranty. If in
doubt, consult a licensed electrician.

No valves between
Tee and main drains

Suction outlet
(main drain)

Suction outlet
(main drain)

Pump

Flow

Valves OK between
pump and Tee

IAPMO Certified
Anti-entrapment
cover or suction
fitting, screw-fastened
to main drain sump

IAPMO Certified
Anti-entrapment
cover or suction
fitting, screw-fastened
to main drain sump

At least

3 Feet

Figure 1

Summary of Contents for Teel 4RJ93

Page 1: ...this symbol on your system or in this manual look for one of the following signal words and be alert to the potential for personal injury Warns about hazards that will cause death serious personal inj...

Page 2: ...icing pump and piping NOTE When connecting threaded pipe directly to pump use Teflon tape or Plasto Joint Stik1 to seal connections Do not use pipe dope pipe dope causes cracking in some plastics and...

Page 3: ...ystem must be six feet per second or less even if one main drain suction fitting is com pletely blocked The flow through the remaining main drain s must comply with the latest ASME ANSI Specifi cation...

Page 4: ...walls of swimming pool spa or hot tub WIRING Pump must be permanently connected to circuit The Wiring Chart below gives correct wire and circuit breaker sizes for the pump alone If other lights or ap...

Page 5: ...Clean and inspect O Ring reinstall on trap cover Replace trap cover on trap turn clockwise to tighten cover NOTE Tighten trap cover by hand only no wrenches Pump should prime now Priming time will dep...

Page 6: ...wer to motor before working on pump or motor Aside from lubricating trap cover O Ring no lubrication or regular maintenance is needed beyond reasonable care and periodic cleaning of strainer basket If...

Page 7: ...tion to jurisdiction LIMITATION OF LIABILITY To the extent allowable under applicable law Dayton s liability for consequential and incidental damages is expressly disclaimed Dayton s liability in all...

Page 8: ...94 WG 17 16 18 19 20 21 22 23 15B 1 2 3 4 5 6 7 8 8A 8B 9 10 See Box A Se Bo 11 12 13 14 15A Please provide following information Model number Serial number if any Part description and number as shown...

Page 9: ...85P C3 185P C3 185P 1 13 Trap cover O Ring U9 375 U9 375 U9 375 1 14 Trap basket C8 58P C8 58P C8 58P 1 15A Drain plug U178 920P U178 920P U178 920P 2 15B 5 16 14 x 5 8 Mounting screw 2 16 Base C4 77P...

Page 10: ...rap and strainer trap or impeller 2 Impeller is clogged 2 Check impeller for clogging Follow steps 1 trough 7 under Removing Old Seal Page 6 Follow steps 7 through 11 under Installing a New Seal Page...