3. Use the “
+
” and “
-
” arrows to adjust the speed in RPM for Quick Clean.
4. Press the
Quick Clean
button again and the display will change to Quick Clean duration. The “Duration”
parameter LED will flash while editing. See
Figure 8
.
Note: The Quick Clean feature does not have a start time.
5. Use the “
+
” and “
-
” arrows to adjust the duration in hours and minutes for Quick Clean.
6. Press the
Start/Stop
button and ensure the LED is illuminated. The pump is now on and will run the
speed and duration set for Quick Clean.
Note:
When the Quick Clean duration ends, the pump resumes the 24 hour schedule at the point where
it normally would be running at that time. The Quick Clean duration will not affect the start or stop times
of the 24 hour schedule. For example, if Quick Clean runs during a period overlapping with a later part of
SPEED 1 and an early part of SPEED 2, the start time of SPEED 3 is not affected.
Note:
Pressing/Holding
Quick Clean
key for more than three (3) seconds will cancel Quick Clean mode.
Note:
During the Quick Clean mode, the pump will not start with the priming sequence.
Note:
It is recommended that you do not set the Quick Clean duration to 0 HRS. Setting the Quick Clean
duration to 0 HRS will not allow you to change the duration setting while the motor is running. The motor
will have to be stopped in order to change the Quick Clean settings if the duration is set to 0 HRS.
The EnviroMAX 1500 Variable Speed Pump user interface has a Keypad Lockout feature to prevent
unwanted changes to the settings. When locked, the keypad will only accept input from pressing the
Display
button to cycle the displayed information on the screen and input to stop the motor from a press of
Start/Stop
button.
The keypad can be locked by pressing and holding the“
1
” button and the
Quick Clean
button at the same
time for at least three seconds. “Loc On” will be displayed if successful.
To unlock the keypad press and hold the “
1
” button and the
Quick Clean
button at the same time for at
least three seconds. “Loc OFF” will be displayed if successful.
Note:
While operating in Keypad Lockout mode the motor can still be stopped by pressing the
Start/Stop
button. However, the motor can not be started again until the user unlocks the keypad.
Keypad Lockout
Key lockout will not prevent the motor from being stopped by pressing the Start/Stop
button. It will then be unable to be restarted until the keypad has been unlocked.
If the motor is operating in Keypad Lockout mode, and being controlled through
external controls, it can only run when the Start/Stop LED is illuminated.
CAUTION
11
SUPERFLO
®
VS Variable Speed Pump Installation and User’s Guide
Quick Clean
The SuperFlo
®
VS Variable Speed Pump is equipped
with a Quick Clean feature, which can be engaged
to temporarily run at higher or lower speeds ranging
between 300 to 3450 RPM. Once the Quick Clean
duration has elapsed, the pump will automatically
return to the programmed schedule.
Programming Quick Clean:
1. Stop the pump if it is running by pressing the
Start/Stop
button.
2. Press the
Quick Clean
button. The LED
above the
Quick Clean
button and the “Speed”
parameter LED will flash while editing. See
Figure 11
.
3. Use the “
+
” and “
-
” arrows to adjust the speed in
RPM for Quick Clean.
4. Press the
Quick Clean
button again and the
display will change to Quick Clean duration. The
“Duration” parameter LED will flash while editing.
See
Figure 12
.
Note:
The Quick Clean feature does not have a
start time.
5. Use the “
+
” and “
-
” arrows to adjust the duration
in hours and minutes for Quick Clean.
6. Press the
Start/Stop
button and ensure the LED
is illuminated. The pump is now on and will run
the speed and duration set for Quick Clean.
Note:
When the Quick Clean duration ends, the pump
resumes the 24 hour schedule at the point where it
normally would be running at that time. The Quick
Clean duration will not affect the start or stop times
of the 24 hour schedule. For example, if Quick Clean
runs during a period overlapping with a later part of
SPEED 1 and an early part of SPEED 2, the start time
of SPEED 3 is not affected.
Note:
Pressing/Holding Quick Clean key for more than
three (3) seconds will cancel Quick Clean mode.
Note:
During the Quick Clean mode, the pump will not
start with the priming sequence.
Note:
It is recommended that you do not set the Quick
Clean duration to 0 HRS. Setting the Quick Clean
duration to 0 HRS will not allow you to change the
duration setting while the motor is running. The motor
will have to be stopped in order to change the Quick
Clean settings if the duration is set to 0 HRS.
Keypad Lockout
The SuperFlo VS Variable Speed Pump user interface
has a Keypad Lockout feature to prevent unwanted
changes to the settings. When locked, the keypad will
only accept input from pressing the
Display
button to
cycle the displayed information on the screen and input
to stop the motor from a press of
Start/Stop
button.
The keypad can be locked by pressing and holding the
“
1”
button and the
Quick Clean
button at the same time
for at least three seconds. “
Loc On
” will be displayed if
successful.
To unlock the keypad press and hold the “
1
” button and
the
Quick Clean
button at the same time for at least
three seconds. “
Loc OFF
” will be displayed if successful.
Note
: While operating in Keypad Lockout mode the motor
can still be stopped by pressing the
Start/Stop
button.
However, the motor can not be started again until the
user unlocks the keypad.
Key lockout will not prevent the motor from being stopped by pressing
the Start/Stop button. It will then be unable to be restarted until the
keypad has been unlocked. If the motor is operating in Keypad Lockout
mode, and being controlled through external controls, it can only run
when the Start/Stop LED is illuminated.
3450
Figure 7: Setting Speed for Quick Clean
2
:
00
Figure 8: Setting Duration for Quick Clean
16
Operation