Control Panel Overview

Keypad Navigation

1.  Speed Buttons 

- Used to select the run speed desired. The LED above the Speed Buttons will 

illuminate when that speed is selected or is currently running. A flashing LED indicates that an 

External Control is active on that speeds channel.

2.  External Control Only LED Indicator

 - Indicates that the pump is operating in External Control Only 

mode. When LED is illuminated the schedule is disabled and the only input is from the low voltage 

external controls.

3.  Start/Stop Button

 - Used to Start and Stop the pump. When the pump is stopped and the LED is not 

illuminated, the pump is unable to run from any type of input.

4.  Display Mode LED Indicators 

- An illuminated LED indicates the information being displayed on the 

screen at any specific point. A flashing LED indicates that the parameter is currently being edited.

5.  Display Button

 - Used to toggle between the different available display modes. This button is also 

used to set the 24-hour clock and screen resolution.

6.  Quick Clean Button

 - Used to run a selected speed and duration programmed for Quick Clean. When 

the LED is illuminated the Quick Clean schedule is active.

7.  Power LED Indicator 

- An illuminated LED indicates that there is live power being supplied to the 

pump.

8.  “

+

” and “

-

” Arrows - Used to make on screen adjustments to the pump settings. The “

+

” arrow 

increases the value of a given setting, while “

-

” decreases the value of a given setting. Pressing and 

holding down either arrow button will increase or decrease the incremental changes faster.

If power is connected to the EnviroMAX 1500 Variable Speed Pump motor, 

pressing any of the following buttons referred to in this section could result in 

the motor starting. Failure to recognize this could result in personal injury or 

damage to equipment.

CAUTION

2

 

SUPERFLO

® 

VS Variable Speed Pump Installation and User’s Guide

If power is connected to the SuperFlo

®

 VS Variable Speed Pump motor, pressing any of the 

following buttons referred to in this section could result in the motor starting. Failure to recognize this 

could result in personal injury or damage to equipment.

CONTROL PANEL OVERVIEW

(1) Speed Buttons

(2) External 

Control Only 

LED Indicator

(3) Start/Stop

Button

(7) Power LED 

Indicator

(4) Display Mode 

LED Indicators

(5) Display Button

(6) Quick Clean 

Button

(8) “+” and “-” 

Arrows

Keypad Navigation

1.   Speed Buttons - Used to select the run speed desired.  The LED above the Speed Buttons will illuminate 

when that speed is selected or is currently running.  A flashing LED indicates that an External Control is 
active on that speeds channel.

2.   External Control Only LED Indicator -  Indicates that the pump is operating in External Control Only 

mode. When LED is illuminated the schedule is disabled and the only input is from the low voltage external 
controls.

3.   Start/Stop Button - Used to Start and Stop the pump.  When the pump is stopped and the LED is not 

illuminated, the pump is unable to run from any type of input.

4.   Display Mode LED Indicators - An illuminated LED indicates the information being displayed on the screen 

at any specific point.  A flashing LED indicates that the parameter is currently being edited.

5.   Display Button - Used to toggle between the different available display modes.  This button is also used to 

set the 24-hour clock and screen resolution.

6.   Quick Clean Button - Used to run a selected speed and duration programmed for Quick Clean.  When the 

LED is illuminated the Quick Clean schedule is active.

7.   Power LED Indicator - An illuminated LED indicates that there is live power being supplied to the pump.

8.   “+” and “-” Arrows - Used to make on screen adjustments to the pump settings.  The “+” arrow increases 

the value of a given setting, while “-” decreases the value of a given setting.  Pressing and holding down 
either arrow button will increase or decrease the incremental changes faster.

10

Operation

Summary of Contents for Sta-rite EnviroMAX 1500

Page 1: ...Variable Speed Pool Pump...

Page 2: ...available When you see the Eco Select brand on one of our products you ll know it is our greenest and most efficient product in that equipment category These products do the best job of saving energy...

Page 3: ...6 Pool Outlets 6 Electrical 7 Equipotential Bonding 7 Operation Priming the Pump 9 Control Panel Overview 10 Setting Clock 11 Using Default Schedule 11 Custom Schedules 12 Operating the Pump While Ru...

Page 4: ...rotected motor prevents damage by automatically shutting down the motor in the event of a locked rotor under voltage over voltage or over current condition and will automatically reduce the speed duri...

Page 5: ...ing IPX6 Inlet Suction ABS Barrel Union to suit 50mm PVC pressure pipe to AS NZS 1477 Outlet Discharge ABS Barrel Union to suit 50mm PVC pressure pipe to AS NZS 1477 Max Total Head 21m Max Working Pre...

Page 6: ...0 2 4 6 8 10 12 14 16 18 20 22 Head m Flow L min 3 1 5 0 R P M 2850RPM 2600RPM 2400RPM 2200RPM 2000RPM 1800RPM 1600RPM 1400RPM 1200RPM 0 50 100 150 200 250 300 350 400 450 500 550 600 650 279mm 515mm...

Page 7: ...ion 200sq cm min inlet outlet and air circulation Allow 200mm to keep rear of motor clear b Have adequate floor drainage to prevent flooding and be protected from excess moisture c Be solid level rigi...

Page 8: ...ly to the pump Additionally if a suitable socket outlet is not available a weatherproof socket must be installed by an electrician in a suitable location RCD tripping indicates an electrical problem I...

Page 9: ...metal piping in accordance with the wiring rules Run a wire from the equipotential bonding terminal on the pump bottom left motor bolt with serrated washer to the pool bonding structure Figure 1 Bondi...

Page 10: ...cate the oring The original equipment O ring contains a permanent internal lubricant a Before removing trap lid SWITCH OFF POWER SUPPLY to pump b CLOSE SHUT OFF VALVES on suction and discharge pipes i...

Page 11: ...e Speed Pump Installation and User s Guide If power is connected to the SuperFlo VS Variable Speed Pump motor pressing any of the following buttons referred to in this section could result in the moto...

Page 12: ...must be pressed and the LED lit for the pump to run 7 OPERATING THE PUMP etting the Clock When the pump is first plugged in the clock will blink o indicate that is has not been set Any daily schedule...

Page 13: ...ill run the custom user programmed schedule 2 00 Figure 5 Setting Duration 8 SUPERFLO VS Variable Speed Pump Installation and User s Guide Custom Schedules To customize the run schedule for your Super...

Page 14: ...custom user programmed schedule Note If the pump has been stopped via the Start Stop button the pump will not run until the pump is turned back on by the Start Stop button If the Start Stop LED is ill...

Page 15: ...ick Clean prior to the duration being completed you can press and hold the Quick Clean button for 3 seconds and the pump will return to the appropriate point in the programmed schedule If power is con...

Page 16: ...le through the following things PrI Priming Speed PrI Remaining Time Once priming has begun the speed can be adjusted between 3450 and 1700 RPM using the and arrows If it is adjusted below 1700 RPM Pr...

Page 17: ...the motor can still be stopped by pressing the Start Stop button However the motor can not be started again until the user unlocks the keypad Keypad Lockout Key lockout will not prevent the motor fro...

Page 18: ...ns Also write down the Priming Speed 3 Press and hold the 1 2 3 and Quick Clean buttons for 3 seconds 4 The screen will display FACt rSt if factory reset is successful See Figure 13 5 Be sure to repro...

Page 19: ...4 shows one of many potential wiring options available to the installer allowing you to install External Controls in the way that best suits your needs Note This 5V Signal red wire is output from the...

Page 20: ...solved by this priority Quick Clean Speed 3 Speed 2 and then Speed 1 External Control Only Mode External Control Only mode will only allow the pump to run from external controls inputs When this mode...

Page 21: ...leaves or debris which could become a fire hazard or choke the motor fan Check that there are no leaks from under the pump If there are this could be a sign of a leaking mechanical seal Call a Pentai...

Page 22: ...p from sucking air Suction lift of 3 to 6 metres will reduce performance Suction lift of more than 6 metres will prevent pumping and cause pump to lose prime In either instance move the pump closer ve...

Page 23: ...section of this manual Reset to default if necessary Motor high temperature limit exceeded Ensure motor fins are clean and fan is intact and free from blockages Ensure adequate ventilation and reduce...

Page 24: ...mproper supply voltage Internal Errors These errors can occur based on operating conditions and the UL 60730 required self diagnostic safety software If they do not clear after multiple restart attemp...

Page 25: ...24 Replacement Parts 4 3 5 11 12 1 10 2 13 15 16 14 8 7 6 9 9a 9b 9c 9d...

Page 26: ...See Pump Fasteners Kit PUMP FASTENERS KIT 1 801280 9 PUMP CASING ASSEMBLY C176 71P 9a LID 1 17307 0111 9b O RING LID 1 35505 1440 9c BASKET 1 C8 58P 9d DRAIN PLUG O RING 2 U178 920P 10 O RING PUMP CA...

Page 27: ...26 Notes...

Page 28: ...664 266 Email au sales pentair com Web www pentairpool com au Information contained here in remains the property of Pentair Australia Pty Ltd Any reproduction display publication modification or dist...